Bonner sphere measurements of 241Am-B and 241Am-F neutron energy spectra unfolded using high-resolution a priori data.

نویسندگان

  • N J Roberts
  • L N Jones
  • Z Z Liu
  • H Tagziria
  • D J Thomas
چکیده

High-resolution neutron energy spectra, covering the entire energy range of interest, for two standard radionuclide neutron sources ((241)Am-B and (241)Am-F) have been derived from Bonner sphere measurements by using high-resolution a priori data in the unfolding process. In each case, two a priori spectra were used, one from a two-stage calculation and also one from a combination of the calculated spectrum with a high-resolution measured spectrum. The unfolded spectra are compared with those published elsewhere and show significant differences from the ISO- and IAEA-recommended spectra for (241)Am-B and (241)Am-F, respectively. Values for the fluence-average energy and fluence-to-dose-equivalent conversion coefficients are presented for the new spectra, and the implications of the new spectra for the emission rates of the sources when measured by the manganese bath technique are also determined.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

استخراج طیف چشمه‌های نوترونی 241Am-Be و 252Cf با استفاده از سامانه طیف‌نگار کره‌های بانر

Bonner spheres system is one of the ways of measuring neutron energy distribution which is often applied in spectrometry and neutron dosimetry. This system includes a thermal neutron detector, being located in the center of several polyethylene spheres, and it is still workable due to the isotropic response of the system which in turn is derived from the spherical symmetry of moderators and the...

متن کامل

Optimization of 241Am-Be emission direction in neutron porosity tools for improving the precision in determining the porosity in calcite formation

Investigation of Hydrocarbon reservoir is important, so it is essential to predict and explore them precisely. One of the methods is well logging, which can transfer the probe or tool in the well to measure one or more characteristics. Nuclear well logging includes radioisotope source and at least one detector. In this work, emission direction of neutrons from the 241Am-Be neutron source toward...

متن کامل

Shielding studies on a total-body neutron activation facility

Background: Prompt gamma neutron activation analysis (PGNAA) is known as a non-invasive technique capable of measuring elemental concentration in voluminous samples in a short period of time. Also it is a valuable diagnostic tool for total body elemental measurements. 252Cf and 241Am-Be sources which are usually used in this method, generate not only neutrons, but also emit high-energy and unwa...

متن کامل

بررسی مقایسه‌ای پاسخ‌دهی و رفتار دزسنج‌های گرماتاب فردی نوترون-گاما در میدان‌های 241Am-Be و 252Cf

Neutron individual dosimetry is challenging subject in dosimetry field. Thermoluminescent dosimeter (TLD) is one of the types of personal dosimeters that is extremely used to determine the doses of neutron sources. Typically, this type of dosimeter is used in different centers with a variety of applications after calibration with a standard neutron radiation sources. Usually, materials of TL cr...

متن کامل

Experimental and Monte Carlo studies on the response of CR-39 detectors to Am-Be neutron spectrum

Background: The Poly-Allyl Diglycol Carbonate (PADC) detector is of particular interest for development of a fast neutron dosimeter. Fast neutrons interact with the constituents of the CR-39 detector and produce H, C and O recoils, as well as (n, α) reaction. These neutron- induced charged particles contribute towards the response of CR-39 detectors. Material and Methods: Electrochemical...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiation protection dosimetry

دوره 161 1-4  شماره 

صفحات  -

تاریخ انتشار 2014