A posteriori accuracy estimation of ultrasonic vector-flow mapping (VFM)
نویسندگان
چکیده
ABSTRACT A novel method, called a posteriori "VFM accuracy estimation" (VAE), for resolving an intrinsic VFM problem is proposed. The problem is that VFM uncertainty can easily vary according to blood flows through an echocardiographic imaged plane (i.e., "through-plane" flows), and it is unknown. Knowing the VFM uncertainty for each patient will make it possible to refine the quality of VFM-based diagnosis. In the present study, VAE was derived on the basis of an error-propagation analysis and a statistical analysis. The accuracy of VAE with a pulsatile left-ventricle phantom was experimentally investigated for realistic cases with through-plane flows. VAE was validated by comparing VFM uncertainty (S.D.) estimated by VAE with VFM uncertainty measured by particle-image velocimetry (PIV) for different imaged planes. VAE accurately estimated the S.D. of VFM uncertainty measured by PIV for all cases with different image planes (R > 0.6 and p < 0.001). These findings on VFM accuracy will provide the basis for widespread clinical application of VFM-based diagnosis. GRAPHICAL ABSTRACT
منابع مشابه
Accuracy and limitations of vector flow mapping: left ventricular phantom validation using stereo particle image velocimetory
BACKGROUND The accuracy of vector flow mapping (VFM) was investigated in comparison to stereo particle image velocimetry (stereo-PIV) measurements using a left ventricular phantom. VFM is an echocardiographic approach to visualizing two-dimensional flow dynamics by estimating the azimuthal component of flow from the mass-conservation equation. VFM provides means of visualizing cardiac flow, but...
متن کاملQuantification of chronic aortic regurgitation by vector flow mapping: a novel echocardiographic method.
AIMS Quantification of aortic regurgitation (AR) using echocardiography is challenging. A newly established echocardiographic method, vector flow mapping (VFM), can directly measure blood flow volume (FV) regardless of rheological characteristics. We intended to assess the accuracy of VFM in the quantification of chronic AR. METHODS AND RESULTS Twenty-one patients with chronic AR, along with ...
متن کاملEvaluation of diastolic blood flow dynamic of the left ventricle in dogs with mitral valve regurgitation using vector flow mapping
Mitral valve regurgitation (MVR) is a common valvular disease in dogs. Hydrokinetic evaluation of the blood flow within the ventricles has become possible by vector flow mapping (VFM), which shows the blood flow within the ventricles in vector and vortex flows. Blood flow within the left ventricle of MVR dogs was compared at different stages of MVR and to that of normal dogs. 14 normal dogs and...
متن کاملAn Estimation of Wave Attenuation Factor in Ultrasonic Assisted Gravity Drainage Process
It has been proved that ultrasonic energy can considerably increase the amount of oil recovery in an immiscible displacement process. Although many studies have been performed on investigating the roles of ultrasonic waves, based on the best of our knowledge, little attention has been paid to evaluate wave attenuation parameter, which is an important parameter in the determination of the energy...
متن کاملApplication of Model-Based Estimation to Time-Delay Estimation of Ultrasonic Testing Signals
Time-Delay-Estimation (TDE) has been a topic of interest in many applications in the past few decades. The emphasis of this work is on the application of model-based estimation (MBE) for TDE of ultrasonic signals used in ultrasonic thickness gaging. Ultrasonic thickness gaging is based on precise measurement of the time difference between successive echoes which reflect back from the back wall ...