Management of acute displaced midshaft clavicular fractures using Herbert cannulated screw: Technique and results in 114 patients
نویسندگان
چکیده
PURPOSE A new and simple operative technique has been developed to provide internal fixation for midshaft clavicle fractures. This involves the use of a large fragment Herbert Screw that is entirely embedded within the bone. Screw fixation is combined with bone grafting from intramedullary reamings of the fracture fragments. The purpose of this report is to assess the outcomes following treatment of midshaft clavicular fracture using this method. MATERIALS AND METHODS One hundred and fourteen patients with acute displaced midshaft fracture were identified between 2002 and 2007. All patients were followed until fracture union. Patients' medical records were reviewed. Disability of the Arm, Shoulder, and Hand questionnaire (DASH), and American Shoulder and Elbow Surgeons Elbow form (ASES) were posted to all patients. Outcome measures included union rate, time to union, implant removal rate, DASH, and ASES scores. RESULTS Patients' median age was 29.5 years (interquartile range, 19-44 years). The most common injury mechanism was sports injury (28%). The median time from injury to surgery was 5 days (interquartile range, 2-9 days). Union occurred in an average of 8.8 weeks. Non-union occurred in three cases (2.6%). The re-operation rate for symptomatic hardware prominence screw was 1.7%. The median DASH score was 0.83 and the median ASES was 100 (n = 35). CONCLUSIONS Intramedullary fixation using cannulated Herbert screw can be used as an effective approach for operative management of midshaft clavicular fractures. Using this method, an appropriate outcome could be achieved and a second intervention for implant removal could be avoided in great majority of cases. LEVEL OF EVIDENCE Level III.
منابع مشابه
Reduction and internal fixation for acute midshaft clavicular fractures by mini-incision using cannulated screws.
UNLABELLED Open reduction and internal fixation of fracture clavicle has typically been done by variable types of plates. Plates carry the disadvantages of longer incisions, prominence of the plates and wound complications. The purpose of this study is to present an alternative surgical technique for acute midshaft clavicular fracture using cannulated 6.5 screws with minimal incision over the f...
متن کاملMidshaft clavicular non-unions treated with the Herbert cannulated bone screw.
PURPOSE To assess an alternative technique for the treatment of midshaft non-unions of the clavicle. METHODS Five patients with symptomatic non-unions of the clavicle were treated with open reduction and intramedullary fixation by using a Herbert cannulated bone screw. Autogenous bone grafting was applied in one case and decortication in the other 4 cases. RESULTS Review of the clinical and...
متن کاملPlate Versus Intramedullary Fixation Care of Displaced Midshaft Clavicular Fractures
In recent decades, there has been a growing trend to the operative treatment of displaced midshaft clavicular fractures. Open reduction and internal plate fixation, and intramedullary nailing fixation are 2 of the widely used techniques for operative treatment, but the optimal fixation method for these types of fractures remains a topic of debate. The objective of this study was to determine th...
متن کاملNonoperative treatment compared with plate fixation of displaced midshaft clavicular fractures.
BACKGROUND Recent studies have shown a high prevalence of symptomatic malunion and nonunion after nonoperative treatment of displaced midshaft clavicular fractures. We sought to compare patient-oriented outcome and complication rates following nonoperative treatment and those after plate fixation of displaced midshaft clavicular fractures. METHODS In a multicenter, prospective clinical trial,...
متن کاملTitanium Elastic Nail (TEN) versus Reconstruction Plate Repair of Midshaft Clavicular Fractures: A Finite Element Study
BACKGROUND The biomechanical characteristics of midshaft clavicular fractures treated with titanium elastic nail (TEN) is unclear. This study aimed to present a biomechanical finite element analysis of biomechanical characteristics involved in TEN fixation and reconstruction plate fixation for midshaft clavicular fractures. METHODS Finite element models of the intact clavicle and of midshaft ...
متن کامل