Hyperpolarized 13C urea myocardial first-pass perfusion imaging using velocity-selective excitation
نویسندگان
چکیده
BACKGROUND A velocity-selective binomial excitation scheme for myocardial first-pass perfusion measurements with hyperpolarized 13C substrates, which preserves bolus magnetization inside the blood pool, is presented. The proposed method is evaluated against gadolinium-enhanced 1H measurements in-vivo. METHODS The proposed excitation with an echo-planar imaging readout was implemented on a clinical CMR system. Dynamic myocardial stress perfusion images were acquired in six healthy pigs after bolus injection of hyperpolarized 13C urea with the velocity-selective vs. conventional excitation, as well as standard 1H gadolinium-enhanced images. Signal-to-noise, contrast-to-noise (CNR) and homogeneity of semi-quantitative perfusion measures were compared between methods based on first-pass signal-intensity time curves extracted from a mid-ventricular slice. Diagnostic feasibility is demonstrated in a case of septal infarction. RESULTS Velocity-selective excitation provides over three-fold reduction in blood pool signal with a two-fold increase in myocardial CNR. Extracted first-pass perfusion curves reveal a significantly reduced variability of semi-quantitative first-pass perfusion measures (12-20%) for velocity-selective excitation compared to conventional excitation (28-93%), comparable to that of reference 1H gadolinium data (9-15%). Overall image quality appears comparable between the velocity-selective hyperpolarized and gadolinium-enhanced imaging. CONCLUSION The feasibility of hyperpolarized 13C first-pass perfusion CMR has been demonstrated in swine. Comparison with reference 1H gadolinium data revealed sufficient data quality and indicates the potential of hyperpolarized perfusion imaging for human applications.
منابع مشابه
Hyperpolarized C urea myocardial first- pass perfusion imaging using velocity- selective excitation
Background: A velocity-selective binomial excitation scheme for myocardial first-pass perfusion measurements with hyperpolarized C substrates, which preserves bolus magnetization inside the blood pool, is presented. The proposed method is evaluated against gadolinium-enhanced H measurements in-vivo. Methods: The proposed excitation with an echo-planar imaging readout was implemented on a clinic...
متن کاملCardiac Perfusion Imaging Using Hyperpolarized 13C Urea Using Flow Sensitizing Gradients
PURPOSE To demonstrate the feasibility of imaging the first passage of a bolus of hyperpolarized (13)C urea through the rodent heart using flow-sensitizing gradients to reduce signal from the blood pool. METHODS A flow-sensitizing bipolar gradient was optimized to reduce the bright signal within the cardiac chambers, enabling improved contrast of the agent within the tissue capillary bed. The...
متن کاملSimultaneous assessment of cardiac metabolism and perfusion using copolarized [1‐13C]pyruvate and 13C‐urea
PURPOSE To demonstrate the feasibility of imaging a bolus of co-polarized [1-13 C]pyruvate and 13 C-urea to simultaneously assess both metabolism and perfusion in the rodent heart. METHODS Copolarized [1-13 C]pyruvate and 13 C-urea was imaged using a multi-echo, flow-sensitized spiral pulse sequence. Healthy rats were scanned in a two-factor factorial design (n = 12 total; metabolism: overnig...
متن کاملCardiac Perfusion Imaging Using Hyperpolarized C Urea Using Flow Sensitizing Gradients
Purpose: To demonstrate the feasibility of imaging the first passage of a bolus of hyperpolarized C urea through the rodent heart using flow-sensitizing gradients to reduce signal from the blood pool. Methods: A flow-sensitizing bipolar gradient was optimized to reduce the bright signal within the cardiac chambers, enabling improved contrast of the agent within the tissue capillary bed. The gra...
متن کاملImaging Renal Urea Handling in Rats at Millimeter Resolution using Hyperpolarized Magnetic Resonance Relaxometry.
In vivo spin spin relaxation time (T2) heterogeneity of hyperpolarized [13C,15N2]urea in the rat kidney was investigated. Selective quenching of the vascular hyperpolarized 13C signal with a macromolecular relaxation agent revealed that a long-T2 component of the [13C,15N2]urea signal originated from the renal extravascular space, thus allowing the vascular and renal filtrate contrast agent poo...
متن کامل