Comparison of fibrin-based clot elasticity parameters measured by free oscillation rheometry (ReoRox®) versus thromboelastometry (ROTEM®)
نویسندگان
چکیده
BACKGROUND Whole blood viscoelastic tests such as the fibrin-based thromboelastometry (ROTEM(®)) test FIBTEM are increasingly used in the perioperative setting to quickly identify deficits in fibrin quality, and to guide hemostatic therapy. The recently developed FibScreen2 test of the ReoRox(®) method, based on free oscillation rheometry, also provides an evaluation of fibrin clot quality. To date, little information is available on the performance of this test in hemodiluted blood, by comparison to FIBTEM. METHODS Whole blood samples from eight healthy volunteers were analyzed using FIBTEM and Fibscreen2. Native and diluted (to 33% and 50% using saline, gelatin or hydroxyethyl starch [HES]) samples were analyzed. Clot strength parameters, including FIBTEM maximum clot firmness (MCF), FIBTEM maximum clot elasticity (MCE) and Fibscreen2 maximum elasticity (G'max), were measured. RESULTS In repeatedly measured samples from two volunteers, FIBTEM MCF and Fibscreen2 G'max revealed a coefficient of variation (CV) of 5.3 vs. 16.3% and 5.6 vs. 31.7% for each volunteer, respectively. Hemodilution decreased clot strength. Both Fibscreen2 G'max and FIBTEM parameters decreased proportionally to the dilution ratio when saline was used. The observed reductions in FIBTEM and Fibscreen2 parameters were more severe in samples diluted with gelatin and HES, compared to saline. Finally, a regression analysis between FIBTEM MCE and Fibscreen2 G'max revealed a poor goodness of fit (r(2) = 0.37, p < 0.0001). CONCLUSIONS ReoRox(®) Fibscreen2 test has a high coefficient of variation, and its application in various hemodilution conditions showed limited comparability with the ROTEM(®) FIBTEM test.
منابع مشابه
Thromboelastometry versus free-oscillation rheometry and enoxaparin versus tinzaparin: an in-vitro study comparing two viscoelastic haemostatic tests' dose-responses to two low molecular weight heparins at the time of withdrawing epidural catheters from ten patients after major surgery.
BACKGROUND Monitoring low molecular weight heparins (LMWH's) in the perioperative period is prudent in patients at high risk of coagulative complications, especially when the patient has an epidural catheter requiring withdrawal, which is associated with the risk of spinal haematoma. The aim of this study was to evaluate the in vitro dose-responses of two different LMWH's on two different visco...
متن کاملAssessing the Methodology for Calculating Platelet Contribution to Clot Strength (Platelet Component) in Thromboelastometry and Thrombelastography
The viscoelastic properties of blood clot have been studied most commonly using thrombelastography (TEG) and thromboelastometry (ROTEM). ROTEM-based bleeding treatment algorithms recommend administering platelets to patients with low EXTEM clot strength (e.g., clot amplitude at 10 minutes [A10] <40 mm) once clot strength of the ROTEM® fibrin-based test (FIBTEM) is corrected. Algorithms based on...
متن کاملIn vitro factor XIII supplementation increases clot firmness in Rotation
Factor XIII (F XIII) is an essential parameter for final clot stability. The purpose of this study was to determine the impact of the addition of factor (F)XIII on clot stability as assessed by Rotation Thromboelastometry (ROTEM®). In 90 intensive care patients ROTEM® measurements were performed after in vitro addition of F XIII 0.32 IU, 0.63 IU, 1.25 IU and compared to diluent controls (DC; aq...
متن کاملFree oscillation rheometry in the assessment of platelet quality
Platelets play an important role in the haemostatic process in order to seal damaged blood vessels. The platelets form a platelet plug at the damaged area and prevent blood loss. Once the damage to the vessel wall has been covered, the platelets retract the coagulum, to allow the blood to flow freely in the vessel. Free oscillation rheometry (FOR) can be used for analysis of coagulation as meas...
متن کاملIn vitro factor XIII supplementation increases clot firmness in Rotation Thromboelastometry (ROTEM).
Factor XIII (F XIII) is an essential parameter for final clot stability. The purpose of this study was to determine the impact of the addition of factor (F)XIII on clot stability as assessed by Rotation Thromboelastometry (ROTEM). In 90 intensive care patients ROTEM measurements were performed after in vitro addition of F XIII 0.32 IU, 0.63 IU, 1.25 IU and compared to diluent controls (DC; aqua...
متن کامل