Impedance-based tissue discrimination for needle guidance.

نویسندگان

  • Håvard Kalvøy
  • Lars Frich
  • Sverre Grimnes
  • Orjan G Martinsen
  • Per Kristian Hol
  • Audun Stubhaug
چکیده

Measurement of electrical impedance can discriminate between tissues of different electrical properties. A measurement system with adequate spatial resolution focused on a volume around the tip of a needle or other invasive clinical equipment can be used to determine in which type of tissue the tip is positioned. We have measured the sensitivity zone of a needle electrode with an active electrode area of 0.3 mm(2), and measured impedance spectra in porcine tissue in vivo. Small electrode impedance data will be influenced by electrode polarization impedance (EPI) at low frequencies. To refine existing methods for needle guidance with higher spatial resolution, we have used multivariate analysis and new interpretations of EPI, and tissue data gathered with selected needle electrodes. The focus of this study is on discrimination between muscle and fat/subdermis for drug administration, but our results also indicate that these refinements will facilitate new clinical applications for impedance-based needle guidance in general.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Surgical Removal of Neglected Soft Tissue Foreign Bodies by Needle-Guided Technique

Introduction: The phenomenon of neglected foreign bodies is a significant cause of morbidity in soft tissue injuries and may present to dermatologists as delayed wound healing, localized cellulitis and inflammation, abscess formation, or foreign body sensation. Localization and removal of neglected soft tissue foreign bodies (STFBs) is complex due to possible inflammation, indurations, granulat...

متن کامل

Improvement of Depth Profiling into Biotissues Using Micro Electrical Impedance Spectroscopy on a Needle with Selective Passivation

A micro electrical impedance spectroscopy (EIS)-on-a-needle for depth profiling (μEoN-DP) with a selective passivation layer (SPL) on a hypodermic needle was recently fabricated to measure the electrical impedance of biotissues along with the penetration depths. The SPL of the μEoN-DP enabled the sensing interdigitated electrodes (IDEs) to contribute predominantly to the measurement by reducing...

متن کامل

Micromachined bulk PZT tissue contrast sensor for fine needle aspiration biopsy.

This paper describes a micromachined piezoelectric sensor, integrated into a cavity at the tip of a biopsy needle, and preliminary experiments to determine if such a device can be used for real-time tissue differentiation, which is needed for needle positioning guidance during fine needle aspiration (FNA) biopsy. The sensor is fabricated from bulk lead zirconate titanate (PZT), using a customiz...

متن کامل

Measurement of needle-tip bioimpedance to facilitate percutaneous access of the urinary and biliary systems: first assessment of an experimental system.

RATIONALE AND OBJECTIVES Percutaneous access to the renal collecting system or biliary system is most frequently performed under image guidance. However, current techniques lack a feedback mechanism to help confirm successful access. A percutaneous needle system has been developed consisting of a modified 18-gauge percutaneous access needle that measures tissue impedance at its needle tip. Init...

متن کامل

Tissue type determination by impedance measurement: A bipolar and monopolar comparison

BACKGROUND In certain medical applications, it is necessary to be able to determine the position of a needle inside the body, specifically with regards to identifying certain tissue types. By measuring the electrical impedance of specific tissue types, it is possible to determine the type of tissue the tip of the needle (or probe) is at. MATERIALS AND METHODS Two methods have been investigate...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physiological measurement

دوره 30 2  شماره 

صفحات  -

تاریخ انتشار 2009