Imaging limbal and scleral vasculature using Swept Source Optical Coherence Tomography.
نویسندگان
چکیده
We demonstrate an application of high-speed swept source optical coherence tomography for vessel visualization in the anterior segment of the human eye. The human corneo-scleral junction and sclera was imaged in vivo. Imaging was performed using a swept source OCT system operating at the 1050nm wavelength range and 100kHz A-scan rate. High imaging speed enables the generation of 3D depth-resolved vasculature maps. The vessel visualization method revealed a rich vascular system in the conjunctiva and episclera.
منابع مشابه
In vivo volumetric depth-resolved vasculature imaging of human limbus and sclera with 1μm swept source phase-variance optical coherence angiography.
We present nnnnnin vivo volumetric depth-resolved vasculature images of the anterior segment of the human eye acquired with phase-variance based motion contrast using a high-speed (100 kHz, 105 A-scans/s) swept source optical coherence tomography system (SSOCT). High phase stability SSOCT imaging was achieved by using a computationally efficient phase stabilization approach. The human corneo-sc...
متن کاملIn Vivo Identification of the Posttrabecular Aqueous Outflow Pathway Using Swept-Source Optical Coherence Tomography.
PURPOSE The purpose of this study was to investigate a novel imaging technique to identify the continuous posttrabecular aqueous outflow pathway from a single B-scan, using swept-source optical coherence tomography (SS-OCT). METHODS Three-dimensional volume scans of the temporal or nasal side of the anterior segment area at the limbus were acquired from 11 eyes of 11 healthy subjects, using S...
متن کاملOptical coherence tomography (OCT) is a low coherence interferometric imaging modality that can perform high- speed and high-resolution cross-sectional and volumetric imaging
We demonstrate an application of high-speed swept source optical coherence tomography for vessel visualization in the anterior segment of the human eye. The human corneo-scleral junction and sclera was imaged in vivo. Imaging was performed using a swept source OCT system operating at the 1050nm wavelength range and 100kHz A-scan rate. High imaging speed enables the generation of 3D depth-resolv...
متن کاملMeasurement of scleral thickness using swept-source optical coherence tomography in patients with open-angle glaucoma and myopia.
PURPOSE To use swept-source optical coherence tomography (OCT) to image the posterior sclera at the posterior pole and around the optic nerve head (ONH) and measure the subfoveal scleral thickness and laminar thickness to evaluate the relationship between the measured thicknesses and ocular parameters. DESIGN Prospective, cross-sectional design. METHODS The study included 103 patients with ...
متن کاملThree-dimensional tomographic features of dome-shaped macula by swept-source optical coherence tomography.
PURPOSE To study the tomographic and pathomorphologic features of dome-shaped maculas with swept-source optical coherence tomography (OCT). DESIGN Prospective, cross-sectional study. METHODS The macular area of 51 highly myopic eyes (35 patients) with dome-shaped maculas was studied with swept-source OCT at 1050 nm. Three-dimensional (3-D) data sets were obtained with raster scanning coveri...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Photonics letters of Poland
دوره 3 4 شماره
صفحات -
تاریخ انتشار 2011