Correlation of visual axis and coronal axis measurements of the optic nerve sheath diameter.

نویسندگان

  • David J Blehar
  • Romolo J Gaspari
  • Anthony Montoya
  • Richard Calderon
چکیده

OBJECTIVE There are several approaches to sonographic imaging and measurement of the optic nerve sheath diameter (ONSD). In this study, we sought to compare visual axis measurements of the optic nerve sheath (ONS) with traditional coronal axis measurements to assess for correlation. METHODS The ONS was visualized in 2 views on both eyes of healthy volunteers using an 8.5-MHz probe. Coronal axis views were obtained with the probe placed at the lateral canthus directed nasally posterior to the globe. Subsequent imaging was made along the midline visual axis. The diameter in this view was measured at several points posterior to the sclera (2, 3, 6, 9, 12, and 15 mm). RESULTS Twenty-seven subjects were enrolled (54 scans). There was a significant difference between ONSDs measured in each axis, with a coronal axis mean diameter of 3.4 mm and visual axis mean diameters at 2, 3, 6, 9, 12, and 15 mm of 4.28, 4.32, 5.15, 5.74, 6.39, and 7.42 mm, respectively (P < .05). The Pearson coefficient showed no correlation between coronal axis and visual axis measurements, with R values ranging from 0.51 to 0.69. There was a statistically significant increase in the ONSD as the nerve coursed posteriorly when measured in the visual axis. CONCLUSIONS Visual axis measurements do not reliably correlate with coronal axis measurements. The consistently larger diameter measured in the visual axis as well as the gradually increasing diameter posteriorly suggests measurement of an artifactual shadow rather than the true ONS.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Coronal Axis Measurement of the Optic Nerve Sheath Diameter.

OBJECTIVES The true optic nerve sheath diameter cutoff value for detecting elevated intracranial pressure is variable. The variability may stem from the technique used to acquire sonographic measurements of the optic nerve sheath diameter as well as sonographic artifacts inherent to the technique. The purpose of this study was to compare the traditional visual axis technique to an infraorbital ...

متن کامل

Effect of scuba-diving on optic nerve and sheath diameters

  Background :There is not any data available about the effect of high bar pressure condition on intracranial pressure. In this study, the effect of diving on the optic nerve and sheath diameters as non-invasive markers of intracranial pressure has been investigated.   Methods : Twenty professional male divers from twenty one volunteers were chosen for this cross-sectional study. Only one perso...

متن کامل

Comparative study measuring optic nerve sheath diameter by transorbital ultrasound in healthy women, pregnant women and pregnant with preeclampsia / eclampsia

Introduction Preeclampsia / eclampsia is a potentially serious disease associated with maternal complications, including neurological. In patients with increased intracranial pressure, the diameter of the optic nerve sheath increases because of its close association with the flow of cerebrospinal fluid. Her measurements using ultrasound transorbital have shown correlation with increased intracr...

متن کامل

Transorbital sonography in acute optic neuritis: a case-control study.

BACKGROUND AND PURPOSE Acute unilateral optic neuritis is associated with a thickening of the retrobulbar portion of the optic nerve as revealed by transorbital sonography, but no comparison has been made between nerve sheath diameter and optic nerve diameter in patients with acute optic neuritis versus healthy controls. We evaluated optic nerve sheath diameter and optic nerve diameter in patie...

متن کامل

Synaptophysin-Positive Neurons in External And Extreme Capsules in Human Brain

Purpose: Externaland extreme capsules are parts of cerebral white matter, and accordingto the classic knowledge they must have no neuronal cell bodies.This researchis designedto find neurons in the external and extreme capsules, and to determine that these neurons are functional or aberrant. Materitais and Methods: Ten adult normal human brains from both sexes were studied using 15,µm serial c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine

دوره 27 3  شماره 

صفحات  -

تاریخ انتشار 2008