Comparison of Octopus Semi-Automated Kinetic Perimetry and Humphrey Peripheral Static Perimetry in Neuro-Ophthalmic Cases
نویسندگان
چکیده
Aim. To compare semikinetic perimetry (SKP) on Octopus 900 perimetry to a peripheral static programme with Humphrey automated perimetry. Methods. Prospective cross-section study comparing Humphrey full field (FF) 120 two zone programme to a screening protocol for SKP on Octopus perimetry. Results were independently graded for presence/absence of field defect plus type and location of defect. Results. 64 patients (113 eyes) underwent dual perimetry assessment. Mean duration of assessment for SKP was 4.54 minutes ±0.18 and 6.17 ± 0.12 for FF120 (P = 0.0001). 80% of results were correctly matched for normal or abnormal visual fields using the I4e target versus FF120, and 73.5% were correctly matched using the I2e target versus FF120. When comparing Octopus results with combined I4e and I2e isopters to the FF120 result, a match for normal or abnormal fields was recorded in 87%. Conclusions. Humphrey perimetry test duration was generally longer than Octopus SKP. In the absence of kinetic perimetry, peripheral static suprathreshold programme options such as FF120 may be useful for detection of visual field defects. However, statokinetic dissociation may occur. Octopus SKP utilising both I4e and I2e targets provides detailed information of both the defect depth and size and may provide a more representative view of the actual visual field defect.
منابع مشابه
Automated combined kinetic and static perimetry: an alternative to standard perimetry in patients with neuro-ophthalmic disease and glaucoma.
OBJECTIVES To create a fully automated, combined perimetry program consisting of a static examination and a kinetic examination, and to compare the results of this test with standard static and kinetic visual fields (VFs). METHODS Fifty-six patients (74 eyes) undergoing neuro-ophthalmic or glaucoma evaluation who had standard static or kinetic perimetry examinations underwent the combined per...
متن کاملComparison of Automated Kinetic and Static Visual Fields in Neuro-ophthalmology Patients
Eighty-three patients with various neuro-ophthalmic diseases were submitted to a standard automated protocol including kinetic and static perimetry The kinetic protocol included one peripheral, one intermediate and one central isopter and a blind spot contour determination The static protocol included fast thresholding of 80 points within the pericentral field and a 4-2-2-2 foveolar threshold d...
متن کاملA comparison of manual kinetic and automated static perimetry in obtaining ptosis fields.
OBJECTIVE To compare examination time and visual field loss for ptosis fields obtained with manual kinetic (Goldmann) perimetry and automated static (Humphrey) perimetry. METHODS Both eyes of 12 patients with bilateral aponeurogenic ptosis were prospectively examined using Goldmann and Humphrey (ptosis protocol) perimetry with the eyelids ptotic and taped into a normal position. RESULTS Bil...
متن کاملComparison of Diagnostic Accuracy between Octopus 900 and Goldmann Kinetic Visual Fields
PURPOSE To determine diagnostic accuracy of kinetic visual field assessment by Octopus 900 perimetry compared with Goldmann perimetry. METHODS Prospective cross section evaluation of 40 control subjects with full visual fields and 50 patients with known visual field loss. Comparison of test duration and area measurement of isopters for Octopus 3, 5, and 10°/sec stimulus speeds. Comparison of ...
متن کاملStudy of Optimal Perimetric Testing in Children (OPTIC): Feasibility, Reliability and Repeatability of Perimetry in Children
PURPOSE To investigate feasibility, reliability and repeatability of perimetry in children. METHODS A prospective, observational study recruiting 154 children aged 5-15 years, without an ophthalmic condition that affects the visual field (controls), identified consecutively between May 2012 and November 2013 from hospital eye clinics. Perimetry was undertaken in a single sitting, with standar...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
دوره 2013 شماره
صفحات -
تاریخ انتشار 2013