Rapid, easy and reliable calibration for freehand 3D ultrasound.

نویسندگان

  • Po-Wei Hsu
  • Richard W Prager
  • Andrew H Gee
  • Graham M Treece
چکیده

This paper presents improvements to the plane-based technique for calibrating freehand 3D ultrasound systems. The improvements are designed to make it easier for inexperienced users to perform plane-based calibration and to know that they have got a reliable result. In particular, we enable the calibration to be performed using water at room temperature while producing a result that is valid for average soft tissue and we show how it is possible to provide feedback on the reliability of the calibration using a metric based on the curvature of the calibration criterion function. We present comprehensive results showing that these innovations improve the precision of the calibration and offer useful feedback to the user.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

First Year Progress Report Rapid, easy and reliable calibration for freehand 3D ultrasound

This paper presents improvements to the plane-based technique for calibrating freehand3D ultrasound systems. The improvements are designed to make it easier for inexperiencedusers to perform plane-based calibration and to know that they have got a reliable result.In particular, we enable the calibration to be performed using water at room temperaturewhile producing a result ...

متن کامل

A Rapid Calibration Method for Registration and 3D Tracking of Ultrasound Images Using Spatial Localizer

Conventional freehand 3D ultrasound (US) is a complex process, involving calibration, scanning, processing, volume reconstruction, and visualization. Prior to calibration, a position sensor is attached to the probe for tagging each image with its position and orientation in space; then calibration process is performed to determine the spatial transformation of the scan plan with respect to the ...

متن کامل

Freehand Three-Dimensional Ultrasound Calibration

Freehand three-dimensional (3D) ultrasound is a technique for acquiring ultrasonic data of a 3D volume with application in radiotherapy and surgery planning. As the clinician sweeps the ultrasound probe over the anatomy, the trajectory of the probe is recorded using an attached position sensor. However, the position sensor tracks the position of the sensor, rather than the ultrasound B-scan. It...

متن کامل

Robust and Automatic Calibration Method for 3D Freehand Ultrasound

This paper describes a new robust and fully automatic method for calibration of three-dimensional (3D) freehand ultrasound. 3D Freehand ultrasound consists in mounting a position sensor on a standard probe. The echographic B-scans can be localized in 3D, and can be compounded into a volume. However, especially for quantitative use, this process dramatically requires a calibration procedure that...

متن کامل

A fully automatic calibration procedure for freehand 3D ultrasound

This paper describes a novel method for calibration of freehand three-dimensional (3D) ultrasound. A position sensor is mounted on a conventional ultrasound probe, thus the set of B-scans can be localized in 3D, and can be compounded into a volume. The calibration process aims at determining the transformation (translations, rotations, scaling) between the coordinates system of images and the c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Ultrasound in medicine & biology

دوره 32 6  شماره 

صفحات  -

تاریخ انتشار 2006