[Effect of the left ventricular pacing site on echocardiographic parameters of ventricular dyssynchrony in patients receiving cardiac resynchronization therapy].
نویسندگان
چکیده
INTRODUCTION AND OBJECTIVES Cardiac resynchronization therapy has been shown to be an option in the treatment of patients with congestive heart failure. The current indication for this treatment is based on clinical and electrocardiographic criteria, although echocardiography has also been shown to be a useful tool for the diagnosis of ventricular dyssynchrony. The aim of this study was to assess left ventricular dyssynchrony by echocardiography and to evaluate the effect of the stimulation site on the magnitude of resynchronization. PATIENTS AND METHOD We studied 25 patients with biventricular stimulation (left ventricular lead located in a lateral position in 13 patients, and in an anterior position in 12). A complete echo-Doppler evaluation, including left ventricular ejection fraction, ventricular diameters and parameters of inter- and intraventricular dyssynchrony, was performed before implantation and 3 months after the procedure, with the device connected and disconnected. RESULTS Left ventricular ejection fraction increased significantly from 23.7 (6.5) to 27.8 (5.5) (P=.007) at 3 months. In the group as a whole, biventricular pacing was associated with a significant decrease in all intraventricular dyssynchrony parameters (septal-to-lateral wall motion delay and septal-to-posterior wall motion delay). This decrease in septal-to-posterior wall motion delay and septal-to-lateral wall motion delay was significantly greater in patients with the electrode implanted in the lateral position (58.1 ms vs 118 ms; P=.02) than with the lead in the anterior position (39.5 ms vs 86.5 ms; P=.04). Three patients, all with the electrode in an anterior location, were considered non-responders. CONCLUSIONS Left lateral free wall stimulation provided significantly better intraventricular resynchronization compared to stimulation at an anterior site. Echocardiography is a useful tool to evaluate changes in intra- and interventricular synchrony related to the pacing site.
منابع مشابه
Absence of additional improvement in outcome of patients receiving cardiac resynchronization therapy paced at the most delayed left ventricular region.
BACKGROUND The choice of the optimal left ventricular (LV) pacing site remains an issue in patients requiring cardiac resynchronization therapy (CRT). AIM This prospective study compared the outcome of patients paced at the most delayed LV region with that of patients paced at any other LV site. METHODS Forty-four patients with severe heart failure underwent three-dimensional (3D) echocardi...
متن کاملThe effects of right ventricular apical pacing on ventricular function and dyssynchrony implications for therapy.
Cardiac pacing is the only effective treatment for patients with sick sinus syndrome and atrioventricular conduction disorders. In cardiac pacing, the endocardial pacing lead is typically positioned at the right ventricular (RV) apex. At the same time, there is increasing indirect evidence, derived from large pacing mode selection trials and observational studies, that conventional RV apical pa...
متن کاملCardiac Resynchronization Therapy: The Remaining Challenges
Cardiac resynchronization therapy (CRT) has come a long way from its inception as a last-ditch attempt to salvage intractable heart failure (HF) in patients with demonstrated electrical dyssynchronies to its current status as a routine mainstream therapy recommended for moderate and even mild HF. The increase in popularity of CRT is due to two main factors: large-scale randomized clinical trial...
متن کاملRapid and Potent Antiarrhythmic Effect of Cardiac Resynchronization Therapy in a Patient with Advanced Dilated Cardiomyopathy and a Large Ventricular Arrhythmia Burden
We report a case demonstrating a rapid and potent antiarrhythmic effect of biventricular pacing. A 67-year-old male patient with dilated cardiomyopathy was admitted for heart failure. The initial surface electrocardiogram revealed a left bundle branch block with a QRS complex duration of 200 ms. Echocardiographic examination revealed a left ventricular ejection fraction of 16%, a left ventricul...
متن کاملQuantitation of basal dyssynchrony and acute resynchronization from left or biventricular pacing by novel echo-contrast variability imaging.
OBJECTIVES This study sought to test a novel echocardiographic method based on contrast variability imaging (CVI), to quantify cardiac dyssynchrony and magnitude of resynchronization achieved by left ventricular (LV) and biventricular (BiV) pacing therapy. BACKGROUND Left ventricular or BiV pacing is a promising new therapy for patients with heart failure and intraventricular conduction delay...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Revista espanola de cardiologia
دوره 57 2 شماره
صفحات -
تاریخ انتشار 2004