Polarized Tips or Surfaces: Consequences in Kelvin Probe Force Microscopy∗
نویسندگان
چکیده
In this work, we present non-contact atomic force microscopy (nc-AFM) and Kelvin probe force microscopy (KPFM) simulations of the (001) surface of silver and supported MgO thin films. From the calculated force spectroscopy, we predict atomic resolution at tip-surface distances of less than 5 Å. For KPFM, we study the influence of charges localized on either the tip or on the surface on the Kelvin voltage. It is shown that the Kelvin voltage changes when the tip is placed above an MgO monolayer, only if the layer has a permanent net dipole. For point charges on the silver surface we examine the lateral resolution in the distance range of 1 to 3 nm, which is the standard working distance in KPFM. We show that point charges appear as nanometer large spots in Kelvin images, which is due to a long-range electrostatic interaction with the tip apex. [DOI: 10.1380/ejssnt.2011.6]
منابع مشابه
AFM tip characterization by Kelvin probe force microscopy
Reliable determination of the surface potential with spatial resolution is key for understanding complex interfaces that range from nanostructured surfaces to molecular systems to biological membranes. In this context, Kelvin probe force microscopy (KPFM) has become the atomic force microscope (AFM) method of choice for mapping the local electrostatic surface potential as it changes laterally d...
متن کاملFacile Preparation of a Platinum Silicide Nanoparticle-Modified Tip Apex for Scanning Kelvin Probe Microscopy
In this study, we propose an ultra-facile approach to prepare a platinum silicide nanoparticle-modified tip apex (PSM tip) used for scanning Kelvin probe microscopy (SKPM). We combined a localized fluoride-assisted galvanic replacement reaction (LFAGRR) and atmospheric microwave annealing (AMA) to deposit a single platinum silicide nanoparticle with a diameter of 32 nm on the apex of a bare sil...
متن کاملGold nanoparticle coated silicon tips for Kelvin probe force microscopy in air.
The tip apex dimensions and geometry of the conductive probe remain the major limitation to the resolution of Kelvin probe force microscopy (KPFM). One of the possible strategies to improve the spatial resolution of surface potential images consists in the development of thinner and more durable conductive tips. In an effort to improve the lateral resolution of topography and surface potential ...
متن کاملPractical aspects of Kelvin probe force microscopy
We discuss practical aspects of Kelvin probe force microscopy ~KFM! which are important to obtain stable images of the electric surface potential distribution at high spatial resolution ~,100 nm! and high potential sensitivity ~,1 mV! on conducting and nonconducting samples. We compare metal-coated and semiconducting tips with respect to their suitability for KFM. Components of the metal coatin...
متن کاملThe effect of patch potentials in Casimir force measurements determined by heterodyne Kelvin probe force microscopy.
Measurements of the Casimir force require the elimination of the electrostatic force between the surfaces. However, due to electrostatic patch potentials, the voltage required to minimize the total force may not be sufficient to completely nullify the electrostatic interaction. Thus, these surface potential variations cause an additional force, which can obscure the Casimir force signal. In thi...
متن کامل