On Critical Frequency and Critical Illumination for Response to Flickered Light
نویسندگان
چکیده
The curve of mean critical flicker frequency as a function of illumination has been determined for the reaction of the sunfish Lepomis to flicker. It exhibits expected quantitative disagreements with the curve of mean critical illumination as a function of flicker frequency in the same organism. The form of the dependence of the variation of critical frequency of flicker upon illumination can be predicted from a knowledge of the way in which variation of critical illumination depends upon flicker frequency. It is pointed out that these findings have an important bearing upon the interpretation of the data of intensity discrimination.
منابع مشابه
Critical Illumination and Critical Frequency for Response to Flickered Light, in Dragonfly Larvae
Curves relating flicker frequency (F) to mean critical illumination (I(m)) for threshold response to flickered light, with equal durations of light and no light intervals, and relating illumination (I) to mean critical flicker frequency (F(m)) for the same response, have been obtained from homogeneous data based upon the reactions of dragonfly larvae (Anax junius). These curves exhibit the prop...
متن کاملCritical Illumination for Response to Flickered Light, with Dragonfly Larvae (anax), in Relation to Area of Eye
Arthropods with large convex eyes provide curves of critical illumination for response as a function of flicker frequency (or of visual acuity) which depart from the probability integral type characteristically found for F - log I with vertebrates. By means of experiments with Anax nymphs in which various parts of the eye have been opaqued it is shown that the special shape of the flicker curve...
متن کاملعوامل موثر بر عملکرد منورهای توان بالا بر پایه منیزیم و نیترات سدیم
Illumination flares from the past to the present have been used in order to create light and signal in critical conditions. Flare formulation consists of three components i. e., fuel (magnesium) and oxidants (sodium nitrate) and a binder. Performance of illumination flares depend on many parameters such as ratio of oxidizer to fuel, particle size of fuel, binder type and binder weight percent. ...
متن کاملA Comparative Study on the Effect of Optical Illumination on Si1-xGex and Si based DDR IMPATT Diodes at W-Band
The effect of optical illumination on DC and dynamic performance of Si1-xGex based double drift region (DDR) (p+pnn+) IMPATT diode operating at W-Band is investigated and compared with its Silicon counterpart. Top Mounted (TM) and Flip Chip (FC) structures are chosen and the composition of photocurrent is altered by shining light on the p+ side and n+ side of the device through optical windows....
متن کاملChanging Therapeutic Paradigms: Predicting mCRC Lesion Response to Selective Internal Radionuclide Therapy (SIRT) based on Critical Absorbed Dose Thresholds: A Case Study
A 65 year old male with metastatic colorectal cancer (mCRC) in the liver was referred for selective internal radionuclide therapy (SIRT) following a history of extensive systemic chemotherapy. 90Y PET imaging was performed immediately after treatment and used to confirm lesion targeting and measure individual lesion absorbed doses. Lesion dosimetry was highly predictive of eventual response in ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Journal of General Physiology
دوره 20 شماره
صفحات -
تاریخ انتشار 1936