Retrieval of dislodged coronary stent from left renal artery by gooseneck snare☆
نویسندگان
چکیده
A rapamycin-eluting stent was dislodged during attempt of implantation at the proximal right coronary artery, which was found by fluoroscopy to have migrated into the anterior trunk of the left renal artery. We chose a 5 mm diameter Amplatz gooseneck snare and successfully retrieved the lost stent from the lodging vessel.
منابع مشابه
Successful Retrieval of Intravascular Stent Remnants With a Combination of Rotational Atherectomy and a Gooseneck Snare
Stent migration from the delivery balloon catheter is a rare but serious complication during percutaneous coronary intervention, particularly when a part of the stent stretches into the aorta. We report an unusual case of stent migration treated with a combination of a gooseneck snare and rotablation. A part of the stent was overstretched and unrolled into the aorta and the rest of the stent re...
متن کاملTwo dislodged and crushed coronary stents: treatment of two simultaneously dislodged stents using crushing techniques
Coronary stent dislodgement is a rare complication of percutaneous coronary intervention. We report a rare case of dislodgement of two intracoronary stents. On withdrawal of two balloon catheters, one with a guide wire was mechanically distorted from the left main (LM) to the proximal left anterior descending artery (LAD) while the other was dislodged from the LM to the ostial left circumflex a...
متن کاملDislodgement of Two Stents in One Patient during Percutaneous Coronary Intervention
Coronary stent loss is a rare but serious complication during interventional cardiology. This complication occurs not only in the intracoronary area but also in the extracoronary area, such as the aortic root or the left ventricle. An 83-year-old man with stable angina had a stent inserted into a heavy calcific left anterior descending artery. The stent was lost twice during the procedure. The ...
متن کاملSuccessful coronary stent retrieval from the ascending aorta using a gooseneck snare kit
Coronary stent dislodgement is a rare complication of percutaneous coronary intervention. We report a case of stent dislodgement in the ascending thoracic aorta. The stent was mechanically distorted in the left circumflex artery (LCX) while being delivered to the proximal LCX lesion. The balloon catheter was withdrawn, but the stent with the guide wire was remained in the ascending thoracic aor...
متن کاملThe successful retrieval of a broken guide wire from the diagonal branch of the left anterior descending coronary artery complicated by partial stent rolling
Percutaneous coronary interventions (PCIs) are relatively safe, and the complication rate is low in comparison to cardiac surgery revascularization. The incidence of broken or retained PCI equipment is about 0.1–0.8% [1]. We report a successful retrieval of a fractured guide wire by using a percutaneous catheter Amplatz GooseNeck Snare and Microsnare Kit (Covidien, Plymouth, USA), which was com...
متن کامل