Measurement of hepatic venous pressure gradient revisited: Catheter wedge vs balloon wedge techniques
نویسندگان
چکیده
AIMS To evaluate the accuracy of measurement of hepatic venous pressure gradient by catheter wedge as compared to balloon wedge (the gold standard). MATERIALS AND METHODS Forty-five patients having a clinical diagnosis of intrahepatic portal hypertension were subjected to the two different types of pressure measurements (catheter wedge and balloon wedge) during transjugular liver biopsy under fluoroscopic guidance. STATISTICAL ANALYSIS Spearman's rank correlation coefficient, Bland-Altman plot for agreement, and single measure intraclass correlation were used for analysis of data. RESULTS There was a close correlation between the results obtained by both the techniques, with highly significant concordance (P < 0.0001). Hepatic venous pressure gradients as measured by the catheter wedge technique were either equal to or less than those obtained by the balloon wedge technique. CONCLUSIONS The difference in hepatic venous pressure gradients measured by the two techniques is insignificant.
منابع مشابه
Pulmonary artery catheterization and wedge pressure measurement in the general intensive therapy unit.
Central venous pressure measurement may be misleading in selective left heart failure and in patients with high pulmonary vascular resistance. More direct information about pulmonary venous pressure and left heart filling pressures may be obtained by catheterization of the pulmonary artery with flow-directed balloon catheters. The use of such catheters, without radiographic control, by those in...
متن کاملUnexpected Collection of Pulmonary Venous Blood from a Pulmonary Artery Catheter: A Case Report
BACKGROUND Pressure and waveform at the catheter tip are continuously monitored during catheterization of pulmonary artery to ensure accurate catheter placement. We present a case in which pulmonary venous blood was unexpectedly collected from the pulmonary artery catheter despite pulmonary artery pressure and waveform detection at the catheter tip, and describe the measures taken to correct th...
متن کاملThe interrelations of the pulmonary arterial and venous wedge pressures.
APRESSURE recorded through a cardiac catheter wedged tightly in a small . pulmonary artery has been referred to as a "capillary," "venous" or "wedge" pressure. On the other hand, a pressure recorded through a cardiac catheter wedged into a pulmonary vein during thoracotomy and in intact animals has been referred to as a pulmonary venous wedge pressure'. Some investigators have found good correl...
متن کاملEffects of blood flow and left atrial pressure on pulmonary venous resistance.
• The contribution of the pulmonary venous system to the pulmonary vascular resistance has been a subject of increasing interest." The pulmonary veins are sometimes considered to consist of wide inactive vessels; however, histological studies have revealed a layer of smooth muscle in these veins, especially at their junction with the left atrium. The veins may also respond histologieally by ven...
متن کاملCorrelation of blood volume values and pulmonary artery catheter measurements.
OBJECTIVE To correlate the values generated by direct total blood volume measurement with pulmonary artery catheter parameters and commonly used laboratory values in the management of critically ill patients. METHODS This study was carried out at the Lutheran Medical Center, Brooklyn, New York, United States of America, during the period 1998-1999. We prospectively correlated the total blood ...