Effects of biocompatible versus standard fluid on peritoneal dialysis outcomes.

نویسندگان

  • David W Johnson
  • Fiona G Brown
  • Margaret Clarke
  • Neil Boudville
  • Tony J Elias
  • Marjorie W Y Foo
  • Bernard Jones
  • Hemant Kulkarni
  • Robyn Langham
  • Dwarakanathan Ranganathan
  • John Schollum
  • Michael Suranyi
  • Seng H Tan
  • David Voss
چکیده

The clinical benefits of using "biocompatible" neutral pH solutions containing low levels of glucose degradation products for peritoneal dialysis compared with standard solutions are uncertain. In this multicenter, open-label, parallel-group, randomized controlled trial, we randomly assigned 185 incident adult peritoneal dialysis patients with residual renal function to use either biocompatible or conventional solution for 2 years. The primary outcome measure was slope of renal function decline. Secondary outcome measures comprised time to anuria, fluid volume status, peritonitis-free survival, technique survival, patient survival, and adverse events. We did not detect a statistically significant difference in the rate of decline of renal function between the two groups as measured by the slopes of GFR: -0.22 and -0.28 ml/min per 1.73 m(2) per month (P=0.17) in the first year in the biocompatible and conventional groups, respectively, and, -0.09 and -0.10 ml/min per 1.73 m(2) per month (P=0.9) in the second year. The biocompatible group exhibited significantly longer times to anuria (P=0.009) and to the first peritonitis episode (P=0.01). This group also had fewer patients develop peritonitis (30% versus 49%) and had lower rates of peritonitis (0.30 versus 0.49 episodes per year, P=0.01). In conclusion, this trial does not support a role for biocompatible fluid in slowing the rate of GFR decline, but it does suggest that biocompatible fluid may delay the onset of anuria and reduce the incidence of peritonitis compared with conventional fluid in peritoneal dialysis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effects of biocompatible compared with standard peritoneal dialysis solutions on peritonitis microbiology, treatment, and outcomes: the balANZ trial.

BACKGROUND A multicenter, multi-country randomized controlled trial (the balANZ study) recently reported that peritonitis rates significantly improved with the use of neutral-pH peritoneal dialysis (PD) solutions low in glucose degradation products ("biocompatible") compared with standard solutions. The present paper reports a secondary outcome analysis of the balANZ trial with respect to perit...

متن کامل

Association of biocompatible peritoneal dialysis solutions with peritonitis risk, treatment, and outcomes.

BACKGROUND AND OBJECTIVES The effect of biocompatible peritoneal dialysis (PD) solutions on PD-related peritonitis is unclear. This study sought to evaluate the relationship between use of biocompatible solutions and the probability of occurrence or clinical outcomes of peritonitis. DESIGN, SETTING, PARTICIPANTS, & MEASUREMENTS The study included all incident Australian patients receiving PD ...

متن کامل

Prospective multicenter observational study of encapsulating peritoneal sclerosis with neutral dialysis solution--the NEXT-PD study.

Many observational studies have been conducted on the occurrence of encapsulating peritoneal sclerosis (EPS). However, poorly biocompatible acidic glucose-based dialysis solutions were used in all previous studies. Today, dialysis solutions that are more biocompatible have become widely available. We therefore initiated a new prospective observational study on the occurrence of EPS. The study d...

متن کامل

The mesothelium under the siege of dialysis solutions: old glucose, new glucose, and glucose-free osmotic agents.

Use of one bag of glucose peritoneal dialysis fluid (PDF) results in the development of a dose-related senescent mesothelial cell phenotype not linked to acidic pH or the presence of lactate buffer. This complication derives mostly from oxidative stress induced both by glucose itself and by glucose degradation products (GDPs). New glucose formulations are offered in dual- or three-chambered bag...

متن کامل

The effect of low glucose degradation product, neutral pH versus standard peritoneal dialysis solutions on peritoneal membrane function: the balANZ trial

BACKGROUND The balANZ trial recently reported that neutral pH, low glucose degradation product (biocompatible) peritoneal dialysis (PD) solutions significantly delayed anuria and reduced peritonitis rates compared with conventional solutions. This article reports a secondary outcome analysis of the balANZ trial with respect to peritoneal membrane function. METHODS Adult, incident PD patients ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American Society of Nephrology : JASN

دوره 23 6  شماره 

صفحات  -

تاریخ انتشار 2012