T2 pitfalls using water as internal reference for metabolite quantification
نویسندگان
چکیده
Introduction The unsupressed water signal is often used as an internal reference for metabolite quantification in H-MRS. The water signal arises from different compartments of the human brain (brain matter BM and cerebral spinal fluid CSF) with large differences of T2 relaxation times between BM and CSF. Bi-exponential fitting of T2 relaxation times can be used to calculate the water signal at TE = 0ms. The knowledge of these T2 relaxation times is crucial to obtain reliable results. In principle the T2 times can be determined with imaging and spectroscopy methods. Additionally, there are several publications reporting T2s with a large range of results (T2 = 110-2000ms) [1-5]. Helms [5] suggested that there is a dependency of the water T2 fit on the voxel's CSF partition. In this study we wanted to compare the results obtainable for T2 with different methods in a typical MRS-Voxel in the anterior cingulated gyrus. Methods Unsupressed water spectra and MRI-T2maps from 23 subjects were obtained on a 3T clinical MR system (TIM Trio, Siemens, Erlangen). We conducted two T2 measurements for an anterior cingulate single voxel MRS location (size: 5.4ml, see Fig. 1). First, we used a PRESS sequence without water suppression with six echo times (TE = 30, 80, 276, 552, 1000, 1500 ms) with a repetition time of TR = 10s. Quantification of the decaying water signal was done with LCModel. Bi-exponential models were fitted to the MRS water signals based on the assumption that the VOI consists solely of BM and CSF. A T1-weighted isotropic 1m 3D MPRage data set was used to determine the compartment-fraction by SPM5 (SegSpec [6]). The exponential functions were weighted by this voxel compartment-fraction and the proton density of BM and CSF in comparison with pure water. Formula: M0*((GMspm*81+WMspm*71)*exp(-TE/T2)+CSFspm*98*exp(-TE/T2)). To investigate the influence from T1, number of obtained echoes and Voxel position, we additionally acquired spectra from a single subject from two VOI locations: an additional VOI was placed in a ventricle. In this experiment both VOIs were examined with two different repetition times (TR = 10s and TR = 30s) to identify a possible T1 relaxation effect and with 14 echo times (TEmin = 30ms, TEmax = 1500ms). Second, we acquired high resolution (1x1x3mm) T2maps using a multiecho imaging sequence, with 31 echoes, (TEmin = 30ms, TEmax = 930ms, ΔTE = 30ms) consisting of 5 slices covering the same volume as the MRS VOI. The multiecho images were fitted by a mono-exponential function and masked by the segmented MRS volume. Mean T2 values for each tissue class were calculated. Only voxels which SPM classified with 100% probability to contain solely BM or CSF were analyzed Results According to the results of image segmentation the examined voxel had a CSF-fraction ranging from 20% to 69%. The bi-exponential fit to the MRS data revealed lower T2 values but similar T2 compared to the T2map fits (Fig. 2). An explorative plot of T2 over CSF content shows a strong dependency for both methods of the evaluated T2 values on the CSF content calculated by the Segmentation algorithm (Fig. 3). The single experiment, where spectra from a VOI with a CSF-fraction of 88% were acquired, indicated that the T2 relaxation time of CSF is at least 1530ms. We found neither a difference in T2 times for TR = 10s compared to TR = 30s, which excludes a T1 effect, nor for the higher number of TEs acquired (14 vs. 6). Discussion Partial volume seems to have a major effect on the T2-estimations leading to better values for the highresolution T2maps. Nevertheless, the map results still have a strong dependency on the global CSF content. There could be two possible reasons for the discrepancies in the measured T2 times. 1: T2 actually changes in restricted volumes over different brain areas. 2: The T1-weighted image based tissue segmentation algorithm largely overestimates the CSF content. To investigate this we used a hypothetical signal decay with the assumption of a T2 of 1730ms [5], T2 = 71ms and T2 = 83ms, randomizing over a wide range of tissue contents we fitted the simulated data with different overand underestimations of the CSF-compartment. An overestimation of CSF by a factor of about 2.86 could best fit our experimental data (Fig. 3). 3: An unknown mechanism or additional compartment, which influences the fitted T2 times and mainly takes effect in partial volume. However, our simulated data showed that signals from myelin water or an additional intermediate component cause an opposite effect. Although the use of tissue segmentation from T1-weighted images for partial volume calculation in MRS metabolite quantifications seems adequate so far, the method is unsatisfactory for the quantification of T2. The bi-exponential fitting procedure exhibits major variances if used in the presence of significant and intra-individually varying amounts of CSF in the voxel. This has direct impacts on the absolute quantification of brain metabolites when water scaling is used. The discrepancy in the measurement of T2 in different brain areas needs some further investigation with high resolution T2maps, avoiding partial volume. References [1] Ernst T. et al. J Magnetic Resonance, Series B 102, 1-8 (1993). [4] Piechnik S. K. et al. Magnetic Resonance in Medicine 61:579–586 (2009). [2] Fletcher M. L. et al. MRM 29:623-630 (1993). [5] Helms G et al. Magnetic Resonance Imaging 19 (2001) 803-811. [3] Haley A. P. et al. Neuroscience Letters 362 (2004) 167–170. [6] Weber-Fahr et al. Neuroimage 2002 May;16(1):49-60. Fig. 2: Results of the two different measurement methods. T2 and T2 of the MRS method have the same value and are identical to T2. Fig. 1: a) Voxel location on T1 image. b) SPM-segmentation of T1 image (only GM and CSF shown). c) Calculated T2map masked by MRS-voxel overlaid with GM-contour. d) Bi-exponential fit to MRS data. e) Mono-exponential fit to CSF-Voxel.
منابع مشابه
Effect of Water T2 Shortening in the Quantification of in-vitro Proton MR Spectroscopy.
PURPOSE This work studies the relationship between in-vitro Proton Magnetic Resonance Spectroscopy metabolite quantification and water T2 decay. MATERIALS AND METHODS An in-vitro correspondence is established between the iron accumulation and the shortening of water T2 relaxation times using seven spherical phantoms, 6 of them were doped with an increasing concentration of iron metal nanopart...
متن کاملERETIC based in vivo H MRSI quantification
Introduction Quantification of metabolite concentrations from spectroscopic images has been performed by a variety of approaches: Absolute quantification based on internal water referencing [1] is the current method of choice. It accounts for B1 variations across the field of view but imposes problems when assessing diseases that lead to alteration of tissue water concentration [2] and relaxati...
متن کاملQuantitation of normal metabolite concentrations in six brain regions by in-vivo 1H-MR spectroscopy
This study examined the concentrations of brain metabolites visible to in-vivo(1)H-Magnetic Resonance Spectroscopy ((1)H-MRS) at 1.5 T in a sample of 28 normal subjects. Quantitation was attempted for inositol compounds, choline units, total creatine and N-acetyl moieties, using open-source software. Six brain regions were considered: frontal and parietal white matter, medial temporal lobe, tha...
متن کاملElectronic reference for absolute quantification of brain metabolites by 1H-MRS on clinical whole-body imaging.
BACKGROUND AND PURPOSE The electronic reference to access in vivo concentrations (ERETIC) method is a promising technique for absolute concentration quantification by brain proton magnetic resonance spectroscopy ((1)H-MRS). However, in its usual form, the technique cannot be implemented in most clinical MR scanners. For this reason, we propose a new strategy for transmitting the ERETIC signal b...
متن کاملIn Vivo Measurement of Relaxation Time of Water and N-acetyl in Intervertebral Disc Using MR Spectroscopy
Introduction Intervertebral disc degeneration (IVDD) related back pain affects about 80% in the general population during the life-time. Traditional imaging techniques rely on disc morphology while actual disc degeneration begins with internal biochemical and biomechanical changes. Proton magnetic resonance spectroscopy (H-MRS) is a powerful non-invasive tool that has been used for the assessme...
متن کامل