Feasible pickup from intact ossicular chain with floating piezoelectric microphone

نویسندگان

  • Hou-Yong Kang
  • Gao Na
  • Fang-Lu Chi
  • Kai Jin
  • Tie-Zheng Pan
  • Zhen Gao
چکیده

OBJECTIVES Many microphones have been developed to meet with the implantable requirement of totally implantable cochlear implant (TICI). However, a biocompatible one without destroying the intactness of the ossicular chain still remains under investigation. Such an implantable floating piezoelectric microphone (FPM) has been manufactured and shows an efficient electroacoustic performance in vitro test at our lab. We examined whether it pick up sensitively from the intact ossicular chain and postulated whether it be an optimal implantable one. METHODS Animal controlled experiment: five adult cats (eight ears) were sacrificed as the model to test the electroacoustic performance of the FPM. Three groups were studied: (1) the experiment group (on malleus): the FPM glued onto the handle of the malleus of the intact ossicular chains; (2) negative control group (in vivo): the FPM only hung into the tympanic cavity; (3) positive control group (Hy-M30): a HiFi commercial microphone placed close to the site of the experiment ear. The testing speaker played pure tones orderly ranged from 0.25 to 8.0 kHz. The FPM inside the ear and the HiFi microphone simultaneously picked up acoustic vibration which recorded as .wav files to analyze. RESULTS The FPM transformed acoustic vibration sensitively and flatly as did the in vitro test across the frequencies above 2.0 kHz, whereas inefficiently below 1.0 kHz for its overloading mass. Although the HiFi microphone presented more efficiently than the FPM did, there was no significant difference at 3.0 kHz and 8.0 kHz. CONCLUSIONS It is feasible to develop such an implantable FPM for future TICIs and TIHAs system on condition that the improvement of Micro Electromechanical System and piezoelectric ceramic material technology would be applied to reduce its weight and minimize its size.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The frequency response of a floating piezoelectric microphone for the implantable middle ear microphone.

OBJECTIVES/HYPOTHESIS A piezoelectric sensor, floating piezoelectric microphone, driven by acoustic vibration of the ossicles, is one possible design for a microphone for a totally implantable cochlear implant. The purpose of the article was to study the frequency response of the floating piezoelectric microphone and to identify the ideal feasible position in the ossicular chain. STUDY DESIGN...

متن کامل

Ossicular Erosion in Patients Requiring Surgery for Cholesteatoma

Introduction: The aim of this study was to evaluate the condition of the ossicular chain in patients requiring surgery for cholesteatoma.  Materials and Methods: In a retrospective analysis, the destruction of the individual and combined bony structures of the ear was described in 166 patients with cholesteatoma who went through surgery in our Otology Center between 2003 and 2009.  Results:...

متن کامل

Vibrations in the human middle ear

BACKGROUND Middle ear surgery techniques can improve hearing destroyed by disease, but results of treatment are difficult to predict. Therefore, researchers use a Laser Doppler Vibrometer to measure vibrations of human middle ear ossicles. MATERIAL/METHODS Measurements of ossicular chain vibrations are performed on fresh human temporal bone specimens using Laser Doppler Vibrometer. Vibrations...

متن کامل

Laser Doppler Vibrometry measurements of human cadaveric tympanic membrane vibration

OBJECTIVE To determine the feasibility of measuring tympanic membrane (TM) vibrations at multiple locations on the TM to differentiate normal eardrums from those with associated ossicular pathologies. DESIGN Cadaveric human temporal bone study. SETTING Basic science laboratory. METHODS A mastoidectomy and facial recess approach was performed on four cadaveric temporal bones to obtain acce...

متن کامل

Conductive Hearing Loss with Present Acoustic Reflex: A Case Report

Acoustic reflex is a sensitive indicator of middle ear lesions when the tympanic membrane is intact and tympanometry is normal. Acoustic reflex is not usually observed in conductive hearing loss caused by disruption of the ossicular chain including ossicular discontinuity and fixation. Ossicular disruption can show at least partially intact acoustic reflex under a certain condition. Moreover, o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2012