An Improved Technique Using the Martell Method with Ellipse Fitting: a Comparitive Study Using a Minimum 5 Year Follow-up of Highly Cross-linked Polyethylene

نویسنده

  • Greene
چکیده

+*Bragdon, C.R; *Greene, M.E; **Martell, J.M; *Geller, J.A.; Kwong, M; *Harris, W.H.; *Malchau, H. +*Orthopaedic Biomechanics and Biomaterials Laboratory, Massachusetts General Hospital, Boston, MA 02114 617-726-3869 fax: 617-726-3883 [email protected] Introduction Highly cross-linked polyethylene has been used as the bearing surface of total hip arthroplasty for over 6 years. Several reports now present data on femoral head penetration into various types of highly cross-linked polyethylene in total hip arthroplasty. A three year follow-up study by Digas et al, using Radiostereometric analysis (RSA) to measure the amount of femoral head penetration, has shown that after the early bedding in period little additional penetration occurred. However, RSA studies are performed on relatively small groups of patients and it is necessary to follow larger groups of patients using nonRSA methods. One of the most commonly used non-RSA methods for measuring femoral head penetration from clinical radiographs is the Hip Analysis Suite software (University of Chicago), (Martell method). The current data on femoral head measurements into various forms of highly cross-linked polyethylene using this and other methods, generally support the results of the RSA studies. However, due to the combination of the low magnitude of femoral head penetration with this new material, variations in film quality, and the resolution of the measuring technique, the prevalence of negative as well as unusually large positive femoral head penetration values are more common. These statistical outliers lend a degree of uncertainty to the data. The main cause of these aberrant measurement results appear to be associated with the elliptical projection artifacts related to variations in the position of the patient relative to the radiographic plate in both the x and y planes. The purpose of this study was to evaluate a group of total hip replacement patients who had received highly cross-linked acetabular components and a minimum 5 year follow-up and compare femoral head penetration results using two modified versions of the Hip Analysis software which employ algorithms for elliptic fittings of the surfaces of the femoral head and acetabular shell. In addition, clinical and radiographic evaluation of outcome of this cohort of THR patients was also conducted. Methods Seventy-six primary total hip replacements (70 patients) in which electron beam HXLPE liners (Longevity or Durasul, Zimmer Inc.) using either a 28mm or a 32mm femoral head with a minimum 5year follow-up (range 5-6.2, average 5.7) were evaluated. The clinical measures used were the Harris Hip, WOMAC, and UCLA activity scores. In addition to the standard clinical radiographic assessment, two versions of the Hip Analysis SuiteTM, (University of Chicago, Chicago Il) software were used to measure the two dimensional change in the position of the center of the femoral head relative to the center of the acetabular component which occurred between the post-operative A/P radiographs of the pelvis and each subsequent radiographic examination. Each version of the software used a new ellipse fitting algorithm. One, Version A, used a standard image matrix while the second, Version B, used a higher pixel matrix of 2X which effectively increased the number of pixels available for defining the best fit ellipse to the femoral and acetabular edge. The results of the Martell analysis are presented as the total average wear rate and standard deviation calculated from the longest follow-up duration. In addition, the penetration rate was derived from the slopes of the linear regression line of all hips with acceptable radiographic pairs. Results The average age of the patients in this study was 64.6 (42 – 88) years with 37 males and 33 females. The average HHS, UCLA and WOMAC scores were 94.3, 8.7 and 18.4 respectively. Median postoperative Harris Hip Score was 90 and the pain score was 40. No component showed radiographic loosening, failure or fracture. There were no osteolytic lesions around the cup or stem. No revisions were performed for polyethylene wear or liner fracture. The average of all penetration rate measurements between all combinations of film pairs for version A and B were 0.03 ± 0.36 mm/yr (range -2.63 to 2.31) and 0.03 ± 0.42 mm/yr (range -2.76 to 2.87), respectively. Figure 1 is a histogram of the data produced with Version B. With Version B the standard deviation of the mean, the range of the data, as well as the overall distribution of the data is improved over Version A. The average femoral head penetration rates and the steady state wear rates measured with the two versions of the software were similar and are summarized in Table 1. There was a significant difference in the average total femoral head penetration rate between the two head size groups when read with Version B, (p=0.01), but not with Version A (p=0.07). The average femoral head penetration did not increase over time after the first year and the steady state wear rates were again significantly different for each head size in Version B (p=0.01), but not Version A (p=0.63).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A comparison of the penetration rate of two polyethylene acetabular liners of different levels of cross-linking. A prospective randomised trial.

We carried out a prospective randomised study designed to compare the penetration rate of acetabular polyethylene inserts of identical design but different levels of cross-linking at a minimum of four years follow-up. A total of 102 patients (102 hips) were randomised to receive either highly cross-linked Durasul, or contemporary Sulene polyethylene inserts at total hip replacement. A single bl...

متن کامل

In vivo wear performance of highly cross-linked polyethylene vs. yttria stabilized zirconia and alumina stabilized zirconia at a mean seven-year follow-up

BACKGROUND Zirconia was introduced as an alternative to alumina for use in the femoral head. The yttria stabilized zirconia material was improved by adding alumina. We evaluated highly cross-linked polyethylene wear performance of zirconia in total hip arthroplasty. The hypothesis was that alumina stabilized zirconia could decrease highly cross-linked polyethylene wear. METHODS Highly cross-l...

متن کامل

Results of Primary Total Hip Arthroplasty Using 36 mm Femoral Heads on 1st Generation Highly Cross Linked Polyethylene in Patients 50 Years and Less with Minimum Five Year Follow-up

PURPOSE We evaluated the clinical and radiographic midterm results of primary total hip arthroplasty (THA) using a 36 mm diameter femoral head on 1st generation highly cross-linked polyethylene (HXLPE) in patients 50 years and less with minimum five year follow-up. MATERIALS AND METHODS We retrospectively reviewed 31 patients (41 hips) aged 50 years and less underwent primary THA with a 36 mm...

متن کامل

Results of Primary Total Hip Arthroplasty with 36-mm Femoral Heads on Highly Cross-linked Polyethylene-Minimum Seven-years Follow-up

PURPOSE We evaluate the clinical and radiographic midterm results of primary total hip arthroplasty (THA) using a 36 mm diameter femoral head on highly cross-linked polyethylene (minimum 7-year follow-up). MATERIALS AND METHODS We retrospectively reviewed 73 patients (74 hips) that underwent primary THA with a 36 mm diameter femoral head on highly cross-linked polyethylene between July 2004 a...

متن کامل

Results of Total Hip Arthroplasty with 36-mm Metallic Femoral Heads on 1st Generation Highly Cross Linked Polyethylene as a Bearing Surface in Less than Forty Year-old Patients: Minimum Ten-year Results

Purpose We evaluated long-term clinical and radiographic results in patients underwent primary total hip arthroplasty (THA) using 36-mm metallic femoral head and 1st generation highly cross-linked polyethylene among patients aged 40 years and less, with minimum 10 years follow-up. Materials and Methods We retrospectively reviewed 20 hips underwent primary THA by one hip surgeon using 36-mm fe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005