Normal human keratocyte density and corneal thickness measurement by using confocal microscopy in vivo.

نویسندگان

  • S Patel
  • J McLaren
  • D Hodge
  • W Bourne
چکیده

PURPOSE To quantify keratocyte density according to stromal region and subject age and to measure the thickness of the normal human cornea and its layers in vivo. METHODS Seventy normal corneas of 70 subjects were examined by confocal microscopy (contact lens wearers were excluded). Ages of subjects ranged from 12 to 80 years, with 10 subjects per decade. Images were recorded by continuously focusing the optical section through the full-thickness central cornea. Two independent human observers manually identified bright objects (keratocyte nuclei) against a dark background to quantify keratocyte density. This method was validated histologically in three human corneas. Thickness measurements were obtained by plotting mean reflected light intensity in images against corneal depth, and calculating distances between intensity peaks that corresponded to corneal layers. RESULTS Full-thickness central keratocyte density was 20,522 +/- 2,981 cells/mm(3) (mean +/- SD, n = 69). The number of keratocytes in a full-thickness column of central stroma, which had a cross-sectional area of 1 mm(2), was 9624 +/- 1385 cells. Keratocyte density was highest in the anterior 10% of the stroma. Full-thickness keratocyte density was correlated with age (r = -0.62, P < 0.001), decreasing 0.45% per year. Central corneal thickness was 563.0 +/- 31.1 microm (mean +/- SD) and central epithelial thickness was 48.6 +/- 5.1 microm. CONCLUSIONS This is the first study to quantify regional keratocyte density comprehensively in vivo across a broad age range of normal human subjects. The method was acceptable to both subject and observer, and may prove useful for quantifying keratocyte density in patients with corneal disorders or after corneal surgery.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Variations of the Normal Human Limbal Stem Cells Detected by In Vivo Confocal Microscopy

Background  To report normal variations of the limbal structures using in vivo laser scanning confocal microscopy. Methods: This was a retrospective study of fourteen eyes from 11 healthy individuals. Confocal imaging of cornea and limbus was performed using Heidelberg Retina Tomograph III Rostock Corneal Module. Results: The typical structure of the palisades of Vogt (POV) was detected ...

متن کامل

Postnatal corneal transparency, keratocyte cell cycle exit and expression of ALDH1A1.

PURPOSE Recent studies have shown that rabbit corneal keratocytes abundantly express two water-soluble proteins, transketolase (TKT) and aldehyde dehydrogenase class 1A1 (ALDH1A1), in vivo and that these proteins may contribute to corneal transparency at the cellular level. The purpose of this study was to determine the relationship between the expression of these proteins and the development o...

متن کامل

Effect of Autologous Serum Eye Drops in Patients with Sjögren Syndrome-related Dry Eye: Clinical and In Vivo Confocal Microscopy Evaluation of the Ocular Surface.

AIM To evaluate in vivo changes after therapy using autologous serum (AS) eye drops in Sjögren's syndrome (SS)-related dry eyes by confocal microscopy. PATIENTS AND METHODS In this study, 24 patients with SS-related dry eyes [12 in AS eye drop therapy and 12 in artificial tear (AT) therapy] and 24 healthy volunteers were recruited. Ocular Surface Disease Index (OSDI), central corneal thicknes...

متن کامل

Histological and confocal microscopy changes in chronic corneal edema: implications for endothelial transplantation.

PURPOSE To report in vivo confocal microscopic (IVCM) features in corneal edema supported by histopathologic correlation. METHODS This was an observational study with evaluation of diagnostic technology. Twenty patients with clinically diagnosed corneal edema were involved, including 11 with Fuchs' endothelial dystrophy (FED). All cases, in addition to a control group of six normal eyes, were...

متن کامل

Automated quantification of keratocyte density by using confocal microscopy in vivo.

PURPOSE To compare keratocyte density determined by using confocal microscopy with keratocyte density determined in the same corneas by histology. METHODS Digital en face images of central corneas were recorded three times by using confocal microscopy in vivo in six New Zealand White rabbits. Bright objects (keratocyte nuclei) in the images were automatically identified by using a custom algo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 42 2  شماره 

صفحات  -

تاریخ انتشار 2001