Improved method for specific determination of creatinine in serum and urine.

نویسنده

  • R J Mitchell
چکیده

The Jaff#{233} reaction is commonly used to determine the concentration of creatinine in urine and serum by measuring the color produced when picric acid and sodium hydroxide solutions are combined with urine or protein-free filtrate from serum. As is well known, substances other than creatinine react to give positive error, the relative amount of interference usually being much greater in serum than in urine. Many specific methods have been proposed for determining creatinine in serum and urine. In several of these, creatinine is separated from interfering substances with strongly acidic cation-exchange resin (1-4). After the creatinine is adsorbed by the resin from an acid solution, it is easily eluted by increasing the pH. Most substances that reportedly interfere with the determination of creatinine by the Jaff#{233} reaction are neutral or anionic and would not be retained on a cation-exchange resin, and so would not interfere with these methods. In the methods of Teger-Nilsson (1), Sadilek (2), and Rockerbie and Rasmussen (4), serum or urine is diluted with weak acid and applied to the resin, which is in the hydrogen form. After adsorption of creatinine and before it is eluted, the resin is converted to the sodium form by washing with a dilute sodium chloride solution. This is necessary because hydrogen ions in the eluate interfere with the Jaff#{233} reaction. During conversion of the resin to the sodium form, creatinine can be eluted from the resin, causing poor recovery and incorrect results. We have developed a method in which the creatinine is separated from serum or urine with a small cation-exchange column in the sodium form at pH 3. After a water wash, the creatinine can be directly eluted with the Jaff#{233} reaction buffer. This rapid and

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ارزیابی روش‌های الکتروایمونواسی و 100Clinitek- برای تشخیص میکروآلبومینوری

Evaluation of Electroimmunoassay and Clinitek-100 for Detection of Microalbuminuria B.A. Jalali Khanabadi PhD , H. Mozaffari Khosravi PhD Received: 12/10/05 Sent for Revision: 04/03/06 Received Revised Manuscript: 20/01/07 Accepted: 25/01/07 Background and Objective: Detection of microalbuminuria is an important laboratory test for evaluation of diabetic complications. A reliable me...

متن کامل

Comparison of Serum Cystatin C and Creati-nine Levels to Evaluate Early Renal Function after Kidney Transplantation

Background: Accurate and rapid assessment of allograft function is essential in renal transplant recipients in order to detect allograft rejection and to monitor drug nephrotoxicity. We aimed to evaluate the usefulness of cystatin C as a marker of kidney allograft function in the early post-transplant period and to compare this value with that of conventional serum creatinine concentration. Met...

متن کامل

Comparison of the Efficacy of Serum Creatinine and Microalbuminuria in Early Diagnosis of Renal Injury in Asphyxiated Infants in Calabar, Southern Nigeria

Background: Microalbuminuria and serum creatinine are the specific markers of acute renal injury. Perinatal asphyxia is responsible for 50% of all neonatal deaths and nonoliguric acute renal injuryis one of its complications. This study was undertaken to determine the efficacy of serum creatinine and microalbuminuria for early diagnosis of renal injury in severely asphyxiated neonates in Calaba...

متن کامل

ارزیابی کمی پروتئینوری با استفاده از نسبت پروتئین به کراتینین در نمونه‌های تصادفی ادرار افراد مبتلا به بیماریهای کلیوی

Quantitation of urinary protein excretion is important for diagnostic and prognostic purposes and to achieve the best treatment. The method most commonly used to measure urinary protein in 24 hour urine samples, are time consuming and often inaccurate. This study performed on 101 persons. Urine samples were collected three times aday. The protein/creatinine ratio(mg:mg) was measured and c...

متن کامل

Development of novel potentiometric sensors for determination of lidocaine hydrochloride in pharmaceutical preparations, serum and urine samples

This article is focused on the determination of lidocaine hydrochloride as a local anaesthetic drug. A potentiometric method based on modified screen-printed and modified carbon paste ion-selective electrodes was described for the determination of lidocaine hydrochloride in different pharmaceutical preparations. It was based on potentiometric titration of lidocaine hydrochloride using modified ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 19 4  شماره 

صفحات  -

تاریخ انتشار 1973