In vitro comparison of the effects of rough and polished stem surface finish on pressure generation in cemented hip arthroplasty

نویسندگان

  • Gavin E Bartlett
  • David J Beard
  • David W Murray
  • Harinderjit S Gill
چکیده

BACKGROUND AND PURPOSE High pressures around implants can cause bone lysis and loosening. We investigated how pressures are generated around cemented femoral stems. METHOD We compared the pressures generated by rough and polished tapered stems at their cement interfaces, in an in vitro model, before and after 1 million load cycles. RESULTS At the start of the study, the loading of both polished and rough stems generated interface pressures that were not statistically significantly different. After 1 million load cycles, the rough stems generated greater interface pressures than at the start (p = 0.03), with maximum pressure wave amplitudes of 450,000 Pa or 3,375 mm Hg. The pressures generated by polished stems were similar before and after 1 million load cycles, and were lower than the pressures generated by the rough stems (p = 0.01). Stem loading caused micromotion between the stem and cement. Polished stems migrated distally in the cement but retained rotational and axial stability. The rough stems also migrated distally and wore the cement mantle, leading to increased rotational instability. INTERPRETATION The change in the rotational micromotion of the rough stem is likely to be the principal cause of the increased stem pump output and to be a key factor in the longevity of cemented femoral implants.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In vitro influence of stem surface finish and mantle conformity on pressure generation in cemented hip arthroplasty

BACKGROUND AND PURPOSE Under physiological loads, debonded cemented femoral stems have been shown to move within their cement mantle and generate a fluid pump that may facilitate peri-prosthetic osteolysis by pressurizing fluid and circulating wear debris. The long-term physiological loading of rough and polished tapered stems in vitro has shown differences in performance, with greater interfac...

متن کامل

Stem subsidence of polished and rough double-taper stems

BACKGROUND AND PURPOSE Many clinical reports have indicated that polished hip stems show better clinical results than rough stems of the same geometry. It is still unknown, however, what the mechanical effects are of different surface finishes on the cement at the cement-bone interface. We compared mechanical effects in an in vitro cemented hip arthroplasty model. METHODS Two sizes of double-...

متن کامل

Effects of prosthesis surface roughness on the failure process of cemented hip implants after stem-cement debonding.

Retrieval studies suggest that the loosening process of the cemented femoral components of total hip arthroplasties is initiated by failure of the bond between the prosthesis and the cement mantle. Finite element (FE) analyses have demonstrated that stem-cement debonding has stress-producing effects in the cement mantle. High interface friction, which corresponds to a degree of surface roughnes...

متن کامل

The effect of surface finish and of vertical ribs on the stability of a cemented femoral stem: an in vitro stair climbing test.

The search for improved femoral fixation in cemented total hip arthroplasty is ongoing. Two design variables, surface finish and stem contour, were evaluated. Sixteen titanium femoral stems of one design were cemented into fiberglass femora. One half of the components had a polished surface and the rest had a roughened finish. Within each group, 4 stems had vertically oriented ribs on the proxi...

متن کامل

Hip Arthroplasty and its Revision in a Child: Case Report and Literature Review

Juvenile idiopathic arthritis is the leading cause of hip replacement in young children. However, arthroplasty in this population is challenging with several concerns about quality of the growing bone, young age for revision surgery, and difficulties in potential several revisions. In this study we introduce a case of a 12-year old who is one of the youngest patients to undergo revision hip art...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 80  شماره 

صفحات  -

تاریخ انتشار 2009