An Ultramicro Oxygen Electrode.

نویسنده

  • I FATT
چکیده

326-pg. 1964.-The advantages of a ~-p-diameter platinum cathode in the Clark-type o:xygen electrode are shown to be freedom from effects due to flow, stirring, or mechanical pressure. When used with a .5-mil polyethylene membrane the I-P electrode shows only a 2 ts difference between a vigorously stirred solution and the unstirred solution. A mechanical pressure of 200 psi on the I-P covered electrode caused only a 20% reduction in current. The use of a 1-p covered electrode as an implant is suggested. electrode implant Clark-type oxygen electrode modification polarographic electrode oxygen measurement platinum electrode S TAUB (7) HAS SHOWN that several important advantages are gained by reduction of the diameter of the platinum cathode in the Clark-type polarographic oxygen electrode (2). I will show here that a reduction of cathode diameter to I /5oth of that used by Staub leads to further advantages. The gas-permeable, membrane-covered oxygen electrode introduced by Clark had a platinum cathode of about 2,000-p diameter. This electrode was sensitive to pressure on the membrane and showed changes in output when the fluid under test was stirred or flowed past at different velocities. A reduction of cathode diameter to 50 p, as reported by Staub, or to 25 1-1, as in the B'eckman-Spinco modified Clark macroelectrode (part no. I 6 I-340, reduced the effect of flow or stirring but did not entirely eliminate it. Rice (5) has prepared I o-p-diameter electrodes but used them uncovered. He did not investigate the effect on output current of flow or pressure on his uncovered electrodes. Charlton's (I) study of a I 00-p membrane-covered electrode did include flow and pressure effects but he did not distinguish between the influence of electrode diameter and membrane thickness. I have prepared electrodes with a platinum cathode diameter of I p which are almost insensitive to flow, stirring, or mechanical pressure when used with a 12-p-thick poly-ethylene membrane. These electrodes have very fast response times, giving a ggyO reading in 30 set in water and in 5 set in gas. The alternative methods of reducing sensitivity to flow rate and pressure when using larger diameter electrodes are to use thicker or less permeable membranes. Both of these alternatives increase the response time and therefore are not as satisfactory as reducing the electrode diameter and using a very thin, highly permeable membrane. Several methods are available for making polarographic oxygen electrodes with a cathode less than …

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prognosis of Occlusive Cerebrovascular Diseases in Normotensive and Hypertensive Subjects

Rossen R, Kabat H, Anderson JP: Acute arrest of cerebral circulation in man. Arch Neurol Psychiat (Chicago) 50: 510-528, 1943 Bicher HI: Brain oxygen autoregulation: A protective reflex to hypoxia? Microvasc Res 8: 291-313, 1974 Bicher HI, Reneau DD, Bruley DF, et al: Brain oxygen supply and neuronal activity under normal and hyperglycemic conditions. Am J Physiol 224: 275-282, 1973 Cater DB, S...

متن کامل

Electrodeposition of platinum nanoparticles on reduced graphene oxide as an efficient catalyst for oxygen reduction reaction

Reduced graphene oxide film was synthesized on a glassy carbon electrode by electro reduction of graphene oxide powders in aqueous solution. Then platinum nano particles were deposited on reduced graphene oxide film that was deposited on the glassy carbon electrode via electro reduction of platinum salt. The Physical morphology of the platinum on reduced graphene oxide film was evaluated by sca...

متن کامل

Single walled carbon nanotube in the reaction layer of gas diffusion electrode for oxygen reduction reaction

In this paper, the effect of surface area of reaction layers in gas diffusion electrodes on oxygen reduction reaction was investigated. For this purpose, various amounts (0.1, 0.2, 0.3, 0.4, 0.5, 1, 1.5 and zero %wt of total loading of reaction layer) of single walled carbon nanotube (SWCNT) were inserted in the reaction layer. The performance of gas diffusion electrodes for oxygen reduction re...

متن کامل

An ultramicro colorimetric method for determination of total and direct serum bilirubin.

A simple reproducible method for the ultramicro determination of total and direct serum bilirubin is presented. This method provides a greater sensitivity than that obtained with other colorimetric ultramicro procedures. Total bilirubin values agree with those obtained with the macro Malloy-Evelyn procedure, but direct-reading bilirubin values were significantly higher with the presented method.

متن کامل

Multichannel Boron Doped Nanocrystalline Diamond Ultramicroelectrode Arrays: Design, Fabrication and Characterization

We report on the fabrication and characterization of an 8 × 8 multichannel Boron Doped Diamond (BDD) ultramicro-electrode array (UMEA). The device combines both the assets of microelectrodes, resulting from conditions in mass transport from the bulk solution toward the electrode, and of BDD's remarkable intrinsic electrochemical properties. The UMEAs were fabricated using an original approach r...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of applied physiology

دوره 19  شماره 

صفحات  -

تاریخ انتشار 1964