A test system for the biological safety cabinet.
نویسنده
چکیده
A simple, cheap and readily available test system for biological safety cabinets is described. It depends on the containment of an aerosol of Bacillus subtilis spores generated in a BIRD micronebulizer and the measurement of air flows with an anemometer. The system was set up to survey new equipment but equally valuable results have been obtained from tests during use. New units were often badly installed and used equipment was poorly maintained. It is suggested that any department which has a need for a biological safety cabinet must be in a position to test its function.
منابع مشابه
ارزیابی عملکرد هودهای بیولوژِیکی ایمن در یک مرکز تحقیقاتی
The use of biological safety cabinets (BSCs) in laboratories has greatly increased over the last few decades. BSCs are used in laboratories to protect both the scientists and the experiments from contamination by biological hazards during tissue culture procedures. The function of BSCs depends upon the HEPA filtration, the fan performance and the airflow patterns in the cabinet. To ensure BSCs ...
متن کاملInactivation of Francisella tularensis Schu S4 in a Biological Safety Cabinet Using Hydrogen Peroxide Fumigation
This study evaluated the inactivation of Francisella tularensis Schu S4 on various materials (acrylic, glass, polyamide, polyethylene, polypropylene, silicone rubber, and stainless steel) using hydrogen peroxide fumigation of a Class III Biological Safety Cabinet (BSC III). A suspension of F. tularensis Schu S4 (7 x 10 CFU) was dried on seven different types of test surfaces and exposed to vapo...
متن کاملخطرات شغلی ناشی از تماس با داروهای آنتی نئوپلاستیک
Chemotherapy is an important part of cancer treatments. In which cytotoxic drugs are used to cure patients. Where as these drugs are therapeutic to patients, they can be toxic to health care providers handling them. Among health care providers, oncology nurses have the responsibility regarding the preparation and administration of antineoplastic drugs. The risk factors associated with antineopl...
متن کاملModified laminar flow biological safety cabinet.
Tests are reported on a modified laminar flow biological safety cabinet in which the return air plenum that conducts air from the work area to the high efficiency particulate air filters is under negative pressure. Freon gas released inside the cabinet could not be detected outside by a freon gas detection method capable of detecting 10(-6) cc/s. When T3 bacteriophage was aerosolized 5 cm outsi...
متن کاملContamination of cultures processed with the isolator lysis-centrifugation blood culture tube.
Overall contamination (on- plus off-streak) of the Isolator (Du Pont Co.) blood culture tube (23%) was greater than that of a conventional broth blood culture bottle (0.6%) or that of a biphasic blood culture bottle (1.3%). To determine the source of this contamination, Isolator cultures of blood from 59 healthy volunteers and of sterile broth from 60 vials were made. A total of 37% of the bloo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical pathology
دوره 27 7 شماره
صفحات -
تاریخ انتشار 1974