Proton-induced X-ray emission analysis - a new tool in quantitative dermatology.

نویسندگان

  • K G Malmqvist
  • L E Carlsson
  • K R Akselsson
  • B Forslind
چکیده

Proton-Induced X-ray Emission analysis (PIXE) constitutes a method for trace element analysis characterized by multielemental capability, detection limits in the low ppm-range and size resolution down towards a micrometre. In applications where the sensitivity of the Electron-Induced X-ray Emission (EIXE) analysis is not sufficient and where a spatial resolution not better than a few micrometres is required, the PIXE technique provides a powerful tool. In this paper properties of the PIXE method are demonstrated by quantitative results from three different samples of dermatological interest. Firstly, mercury results from a longitudinal scan of a single hair strand from a mercury poisoned person are shown. With a spatial resolution of one or a few millimetres very fast scans may be performed on hair strands giving information on time and magnitude of intoxication or other exposures, as well as deficiencies. Secondly, results are given from a radial scan with a beam width of 4 micron on hair from a person exposed to high amounts of iron. The calcium, iron and zinc distributions but not the sulphur and potassium distributions show narrow peaks of concentration (less than 4 micron) about 15 micron from the surface of the hair. Further investigations have to be performed in order to interpret these data. Thirdly, the depth profiles in skin of some elements were measured with a beam width of 10 micron. The results show significant increases in sulphur, calcium and zinc concentrations and significant decreases in phosphorous and potassium concentrations at the skin surface, i.e. in the stratum corneum.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A proton induced X-ray emission (PIXE) analysis of concentration of trace elements in varicose veins

Background: Proton induced X-ray emission (PIXE) has been applied as reliable and improved techniques in this study to compare concentration of various trace elements in normal and abnormal varicose veins. Materials and Methods: Five samples from normal veins and 13 samples from varicose veins bombarded by 2.0 MeV energy proton beams produced by a Van de Graff accelerator in vacuum. T...

متن کامل

Investigation of heavy trace elements in neoplastic and non-neoplastic human thyroid tissue: A study by proton-induced X-ray emissions.

Background: Within the context of developing techniques to facilitate the diagnosis of the thyroid diseases, the elemental composition of pathological thyroid tissue (neoplastic and non-neoplastic) was investigated by proton induced X-ray emission. The PIXE has been widely used as a sensitive technique for trace elemental analysis in both biological and medical fields. Materials and Methods: Th...

متن کامل

Micro-pixe analysis in invasive ductal carcinoma tissues after treatment of astaxanthin

Background: Trace elements play an important role in a number of biological processes. Astaxanthin (ASX), a carotoid pigment found in certain marine plant and animals, has shown anti cancer and anti free radical properties. This work intended to understand the effect of Astaxanthin in breast cancer (invasive ductal carcinoma, IDC) by using micro-pixe method. For this aim the concentratio...

متن کامل

Pulsed DC- Plasma Assisted Chemical Vapor Deposition of α-rich Nanostructured Tantalum Film: Synthesis and Characterization

This paper is an attempt to synthesize nanostructured tantalum films on medical grade AISI 316L stainless steel (SS) using pulsed DC plasma assisted chemical vapor deposition (PACVD). The impact of duty cycle (17-33%) and total pressure (3-10 torr) were studied using field emission scanning electron microscopy (FESEM), grazing incidence x-ray diffraction (GIXRD), nuclear reaction analysis (NRA)...

متن کامل

A pixe analysis for measuring the trace elements concentration in breast tissue of Iranian women

Background: A powerful and improved technique, Proton Induced X-ray Emission (PIXE) has been performed-yielding the elemental composition of 17 samples of surgically excised malignant and normal tumors of breast tissue. The samples without any further process as thick targets were put on capton foil backing. There are no homogenizing processes. The PIXE spectra analysis was performed using he n...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Scanning electron microscopy

دوره Pt 4  شماره 

صفحات  -

تاریخ انتشار 1983