OBJECTIVE Complications are important determining factors for safety of endoscopic submucosal dissection (ESD). ESD of large lesions is associated with increased procedural time. This study investigated whether double-channel gastroscope could be used to reduce procedural time in gastric antrum ESD. METHODS A retrospective cohort study of 46 patients with one gastric antrum lesion resected by ESD was conducted between January 2013 and December 2015. The diameter of a lesion was from 2cm to 4cm in 46 patients. EUS before ESD was used to evaluate the submucosal vascular structure and the location of lesion in gastric wall. Forty six lesions had ESD with either the ordinary gastroscope (OS group) (n=24) or the double-channel gastroscope (DC group) (n=22). RESULTS The mean procedural time was significantly lower in the DC group than in the OS group (49.1 minutes vs. 20.5 minutes, p=0.04). There were no significant differences in submucosal injection frequency, specimen size, en bloc resection rate and perforation rate between the two endoscopic groups. There was no recurrence in any case during the follow-up period. CONCLUSIONS Our data suggest that ESD utilizing double-channel gastroscope may provide a better platform for quicker ESD with equal safety.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Is the Double Channel Gastroscope Useful in Endoscopic Mucosal Resection for Large Sessile Colon Polyps?

colon polyps are less than 1 cm in size. However, en-doscopists often encounter large sessile colon polyps greater than 2 cm in practice. Removal of a large sessile colon polyp is difficult due to a high rate of procedure-related complications , such as bleeding and perforation. Therefore, patients with large sessile colon polyps are referred to a tertiary hospital for appropriate treatment. Th...

متن کامل

Use of a Double-Channel Gastroscope Reduces Procedural Time in Large Left-Sided Colonic Endoscopic Mucosal Resections

BACKGROUND/AIMS Endoscopic mucosal resection (EMR) of large colorectal lesions is associated with increased procedural time. The objective of this study was to evaluate the effect of double-channel gastroscope (DCG) use on the procedural time of EMRs in the rectosigmoid area. METHODS All EMRs for sessile or flat rectosigmoid lesions ≥2 cm performed between July 2011 and September 2012 were re...

متن کامل

Is the Endoscopic Grasp-and-Traction Device Useful for Endoscopic Submucosal Dissection in Treating Early Gastric Cancer?

has become possible to achieve en bloc and histologically complete resection of gastric tumors with endoscopic submu-cosal dissection (ESD), regardless of size, allowing for the re-section of tumors that would not have been previously possible. 1,2 However, ESD is a challenging technique with a higher complication rate than that of endoscopic mucosal resection. The main difficulty of ESD is the...

متن کامل

Pictures in Digestive Pathology

An 80-year-old woman was diagnosed of a 10 cm colorectal laterally spreading tumor granular-type in the splenic flexure (Fig. 1). Endoscopic submucosal dissection (ESD) was performed but pediatric colonoscope approach (PCF-Q260JI, Olympus, Japan) was technically difficult due to the narrow transverse colon working space. Then, single-balloon endoscopy system using a 3.2 mm channel gastroscope (...

متن کامل

The suture-pulley method for endolumenal triangulation in endoscopic submucosal dissection.

is a time-consuming and technically demanding technique [1–3]. The main difficulty is the lack of triangulated countertraction with current endoscopes [4]. To improve speed and efficacy of the procedure, an intriguing pulley method using dental floss together with endoscopic clips has recently been described [5]. However, current clip technology is unlikely to provide a robust and dependable an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 32  شماره 

صفحات  -

تاریخ انتشار 2016