AIM To compare the effect of suction on the macular thickness and retinal nerve fiber layer (RNFL) thickness during laser in situ keratomileusis (LASIK) used Ziemer FEMTO LDV femtosecond laser (Ziemer group) and Moria M2 automated microkeratome (Moria group) for flap creation. METHODS Fourier-domain optical coherence tomography (FD-OCT) was used to measure macular thickness, ganglion cell complex thickness and (RNFL) thickness of 204 eyes of 102 patients with the Ziemer femtosecond laser (102 eyes) and the Moria M2 microkeratome (102 eyes) before surgery and 30min; 1, 3d; 1wk; 1, 3mo; 1y after surgery. RESULTS The average foveal thickness and parafoveal retinal thickness 30min after the surgery were statistically more than that before surgery (Ziemer P<0.001, P=0.003 and Moria P=0.001, P=0.006) and the effect was less in the Ziemer group than that in the Moria group (P all<0.05). The ganglion cell complex thickness was not significantly changed in both groups (P all>0.05). The RNFL thickness was statistically less 30min after surgery in both groups (P=0.014, P<0.001), but the influence was less in Ziemer group than that in Moria group (P=0.038). However, the RNFL thickness had recovered to the preoperative level only 1d after surgery. CONCLUSION The suction of femtosecond laser and mechanical microkeratome led to the increase in macular central fovea thickness and the decrease in RNFL thickness values at the early stage after LASIK. The effect of suction on macular and the RNFL thicknesses in Ziemer group is smaller than that in Moria group.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Changes in retinal nerve fiber layer thickness following mechanical microkeratome-assisted versus femtosecond laser-assisted LASIK

PURPOSE To study the influence of the transient elevation of intraocular pressure during suction in laser-assisted in situ keratomileusis (LASIK) on the retinal nerve fiber layer (RNFL) thickness both in microkeratome assisted and femotsecond (FS) LASIK. PATIENTS AND METHODS An interventional case series that included 40 eyes suffering from myopia who were candidates for LASIK. All underwent ...

متن کامل

The Effect of LASIK Procedure on Peripapillary Retinal Nerve Fiber Layer and Macular Ganglion Cell-Inner Plexiform Layer Thickness in Myopic Eyes

PURPOSE To evaluate the effect of applied suction during microkeratome-assisted laser in situ keratomileusis (LASIK) procedure on peripapillary retinal nerve fiber layer (RNFL) thickness as well as macular ganglion cell-inner plexiform layer (GC-IPL) thickness. METHODS 89 patients (124 eyes) with established myopia range from -3.0 to -8.0 diopters and no associated ocular diseases were includ...

متن کامل

Incidence of Posterior Vitreous Detachment After Femtosecond LASIK Compared With Microkeratome LASIK.

PURPOSE To compare the incidence of posterior vitreous detachment (PVD) after femtosecond and microkeratome laser in situ keratomileusis (LASIK). SETTING Rowad Correction Centre, Cairo, Egypt (a private center affiliated to Cairo University). DESIGN Prospective, nonrandomized comparative unmasked study. METHODS The study was conducted at a single laser center. Eligible patients chose betw...

متن کامل

Corneal flap thickness with the Moria M2 single-use head 90 microkeratome in 72 consecutive LASIK procedures

PURPOSE This study aimed to evaluate the accuracy and consistency of corneal flap thickness in laser-assisted in situ keratomileusis (LASIK) with the Moria M2 single-use head 90 microkeratome. METHODS The central corneal thickness of 72 (37 right, 35 left) eyes of 37 patients was measured by ultrasonic pachymetry preoperatively and intraoperatively after flap cut. The Moria M2 single-use head...

متن کامل

Three-dimensional LASIK flap thickness variability: topographic central, paracentral and peripheral assessment, in flaps created by a mechanical microkeratome (M2) and two different femtosecond lasers (FS60 and FS200)

PURPOSE To evaluate programmed versus achieved laser-assisted in situ keratomileusis (LASIK) flap central thickness and investigate topographic flap thickness variability, as well as the effect of potential epithelial remodeling interference on flap thickness variability. PATIENTS AND METHODS Flap thickness was investigated in 110 eyes that had had bilateral myopic LASIK several years ago (av...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • International journal of ophthalmology

دوره 8 4  شماره 

صفحات  -

تاریخ انتشار 2015