Performance of an X-ray single pixel TES microcalorimeter under DC and AC biasing
نویسندگان
چکیده
We are developing Frequency Domain Multiplexing (FDM) for the read-out of TES imaging microcalorimeter arrays for future X-ray missions like IXO. In the FDM configuration the TES is AC voltage biased at a well defined frequencies (between 0.3 to 10MHz) and acts as an AM modulating element. In this paper we will present a full comparison of the performance of a TES microcalorimeter under DC bias and AC bias at a frequency of 370kHz. In both cases we measured the current-to-voltage characteristics, the complex impedance, the noise, the X-ray responsivity, and energy resolution. The behaviour is very similar in both cases, but deviations in performances are observed for detector working points low in the superconducting transition (R/RN < 0.5). The measured energy resolution at 5.89keV is 2.7eV for DC bias and 3.7eV for AC bias, while the baseline resolution is 2.8eV and 3.3eV, respectively.
منابع مشابه
Study of the Dependency on Magnetic Field and Bias Voltage of an AC-Biased TES Microcalorimeter
At SRON we are studying the performance of a Goddard Space Flight Center single pixel TES microcalorimeter operated in an AC bias configuration. For x-ray photons at 6 keV the pixel shows an x-ray energy resolution ΔEFWHM =3.7 eV, which is about a factor 2 worse than the energy resolution observed in an identical DC-biased pixel. In order to better understand the reasons for this discrepancy we...
متن کاملResponse of a Superconducting Transition-Edge Sensor Microcalorimeter with a Mushroom-shaped Absorber to L X-rays Emitted by Transuranium Elements
A four-pixel-array superconducting transition-edge sensor (TES) microcalorimeter with a mushroom-shaped absorber was fabricated for the energy dispersive spectroscopy performed on a transmission electron microscope. The TES consists of a bilayer of Au/Ti with either a 50nm or 120-nm thickness. The absorber of 5.0 μm thick is made from a Au layer and its stem is deposited in the center of the TE...
متن کاملQuantitative Analysis with the Transition Edge Sensor Microcalorimeter X-ray Detector
The use of a microcalorimeter X-ray detector with a transition edge sensor in an electron probe to perform quantitative analysis is reported. Two bulk samples of multielement glasses that have been previously characterized by chemical methods for use as standard reference materials were analyzed. The spectra were analyzed against standards using three different correction schemes. In one of the...
متن کاملThermal design issues and performance of microcalorimeter arrays at sub-Kelvin temperatures - Sensors, 2003. Proceedings of IEEE
We have produced 5 x 5 pixel arrays of microcalorimeters using bulk micromachining. Analysis of our data provides the thermal conductivity parameters of SixNy I p m thick membranes at 100 mK. Moreover wefind that the thermal transport at 100 mK in Si beams, with dimensions 1.25 mm x 0.35” x 35pm (length x height x width) is dominated by ballistic phonons with a mean free path of 110 pn. These t...
متن کاملOn-grid and Off-grid Operation of Multi-Input Single-Output DC/DC Converter based Fuel Cell Generation System
This paper presents the modeling and simulation of a proton exchange membrane fuel cell (PEMFC) generation system for off-grid and on-grid operation and configuration. A fuel cell DG system consists of a fuel cell power plant, a DC/DC converter and a DC/AC inverter. The dynamic model for fuel cell array and its power electronic interfacing are presented also a multi-input single output (MISO) D...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2016