Re: Biventricular pacing does not affect microvolt T-wave alternans in heart failure patients.

نویسنده

  • John E Madias
چکیده

BACKGROUND Microvolt T-wave alternans (MTWA) is a valuable tool for stratification of patients at risk for sudden death and has recently been approved for this purpose by Medicare. Although right atrial (RA) pacing has been applied for MTWA testing, the effects of other pacing modalities on MTWA have not been systematically studied. Accordingly, it is unknown whether biventricular (BiV) pacing might influence MTWA test results. OBJECTIVE This study sought to investigate effects of BiV pacing in comparison with other pacing modalities. METHODS Congestive heart failure patients (n = 30) receiving cardiac resynchronization therapy were included, and a systematic step-up pacing protocol was performed via the implanted cardioverter-defibrillator. RESULTS Of the overall 120 MTWA tests performed, 67 (56%) were nonnegative. Nonnegative MTWA test results were observed in 18 patients (60%) during RA stimulation, whereas 17 (57%), 15 (50%), and 17 test results (57%) were nonnegative during right ventricular (RV), left ventricular (LV), and BiV pacing, respectively. Seven (23%) patients were MTWA negative for all pacing sites. Results of MTWA assessment during RA pacing were concordant with results obtained with RV pacing in 25 (83%) patients (kappa = 0.66, P = .0003), to LV pacing in 21 (70%) patients (kappa = 0.4, P = .025), and to BiV pacing in 25 (83%) patients (kappa = 0.66, P = .0003). Positive and negative predictive values of nonnegative MTWA test results obtained during RA pacing for a similar result obtained with RV pacing were 88% and 76%. Respective values were similar for other pacing modalities (80% and 60% for LV; 88% and 76% for BiV pacing). CONCLUSION There is a high level of concordance between MTWA test results obtained during RA pacing and other pacing modalities, and MTWA assessment seems not to be influenced by BiV stimulation in congestive heart failure patients. In general, BiV pacing does not seem to affect an arrhythmogenic substrate as detected by MTWA testing.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The immediate reproducibility of T wave alternans during bicycle exercise.

A number of recent studies have demonstrated that the microvolt level T wave alternans measured during bicycle exercise can identify patients at high risk for developing malignant ventricular arrhythmias. However, little is known about the reproducibility of T wave alternans measured during bicycle exercise. The purpose of this study was to prospectively evaluate the immediate reproducibility o...

متن کامل

Microvolt T-wave alternans testing should be used to guide arrhythmic therapy in heart failure patients.

Microvolt T-wave alternans testing should be used to guide arrhythmic therapy in heart failure patients. The MIT Faculty has made this article openly available. Please share how this access benefits you. Your story matters.

متن کامل

Predictive value of T-wave alternans for arrhythmic events in patients with congestive heart failure.

Measurement of microvolt level T-wave alternans in the surface electrocardiogram is a novel way to assess the risk of ventricular arrhythmias. Seven tests of arrhythmic risk, including T-wave alternans, were undertaken in 107 consecutive patients with congestive heart failure and no history of sustained ventricular arrhythmias; the patients were followed up for arrhythmic events during the next...

متن کامل

Influence of heart rate and sympathetic stimulation on arrhythmogenic T wave alternans.

We determined the temporal stability of T wave alternans (TWA) during constant rate stimulation and the dependence of alternans on heart rate (HR) and beta-adrenergic stimulation. Although it is established that exercise can provoke microvolt-level TWA in patients at risk for reentrant ventricular arrhythmias, the mechanisms underlying TWA in humans are not well understood. Specifically, the te...

متن کامل

Spontaneous ventricular tachycardia and fibrillation in a patient with a positive microvolt T wave alternans test and negative electrophysiological study.

This report describes a patient with a previous myocardial infarction who presented with syncope. The patient had a positive microvolt T wave alternans test, a negative electrophysiological study, and a normal heart rate variability. In hospital, the patient had episodes of ventricular tachycardia and fibrillation. An implantable cardioverter defibrillator was implanted and during the following...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Heart rhythm

دوره 5 3  شماره 

صفحات  -

تاریخ انتشار 2008