Simultaneous bilateral internal carotid artery 3D rotational angiography.

نویسندگان

  • Joon K Song
  • Yasunari Niimi
  • Jonathan L Brisman
  • Alejandro Berenstein
چکیده

We simultaneously injected both internal carotid arteries (ICAs) during 3D rotational digital subtraction angiography in a patient with a ruptured anterior communicating artery (Acom) aneurysm and vasospasm. Shaded surface display (SSD) images from this acquisition provided more anatomic detail than did SSD images created from individual ICA 3D rotational digital subtraction angriography. In the evaluation of complex Acom aneurysms, this technique can facilitate the choice of optimal working projections for safer aneurysm coiling.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Internal carotid artery stenosis measurement: comparison of 3D computed rotational angiography and conventional digital subtraction angiography.

BACKGROUND AND PURPOSE Clinical trials have shown that carotid endarterectomy reduces stroke risk in symptomatic individuals with severe internal carotid artery (ICA) stenosis. As a result of these trials, digital subtraction angiography (DSA) became a standard of reference for ICA stenosis diagnosis. Newer 3D techniques provide a larger number of views than DSA, which may influence the estimat...

متن کامل

Diagnostic Accuracy of Magnetic Resonance Angiography for Cerebral Aneurysms in Correlation With 3D–Digital Subtraction Angiographic Images

Background and Purpose—We investigated the sensitivity of 3D–time-of flight (3D-TOF) magnetic resonance angiography (MRA) in the detection of cerebral aneurysms with the use of 3D digital subtraction angiography as the gold standard. We also evaluated the effects of location and number of aneurysms (and experience of the reader) on the sensitivity. Methods—3D-TOF MRA was performed in 82 patient...

متن کامل

Imaging of Distal Dural Ring Plane and Paraclinoid Internal Carotid Artery Aneurysms with 3D Rotational Angiography

Department of Neurosurgery, Cheju Halla Hospital, Jejudo, Korea; Department of Radiology, and Department of Neurosurgery, The Catholic University of Korea, Seoul, Korea; Department of Neurosurgery, Inha University School of Medicine, Incheon, Korea Received March 2, 2010; accepted after revision May 16, 2010. Correspondence to: Bum-soo Kim, MD, Department of Radiology, Seoul St. Mary’s Hospital...

متن کامل

Diagnostic accuracy of magnetic resonance angiography for cerebral aneurysms in correlation with 3D-digital subtraction angiographic images: a study of 133 aneurysms.

BACKGROUND AND PURPOSE We investigated the sensitivity of 3D-time-of flight (3D-TOF) magnetic resonance angiography (MRA) in the detection of cerebral aneurysms with the use of 3D digital subtraction angiography as the gold standard. We also evaluated the effects of location and number of aneurysms (and experience of the reader) on the sensitivity. METHODS 3D-TOF MRA was performed in 82 patie...

متن کامل

Angiographic anatomy of the extracranial and intracranial portions of the internal carotid arteries in donkeys

BACKGROUND In horses, the extracranial and intracranial pathway of the internal carotid artery has been described. The extracranial pathway of the internal carotid artery begins at the carotid termination and runs on the dorsal surface of the medial compartment of the guttural pouch. Thereafter the internal carotid artery passes through the foramen lacerum to continue intracranially, forming pa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 25 10  شماره 

صفحات  -

تاریخ انتشار 2004