Precise Half-Life Measurement of Ga
نویسندگان
چکیده
In last year’s Progress Report we reported on measurements of the β-decay of Ga, including a preliminary value for its halflife [1]. We report here on an additional measurement of the half-life focused on exposing systematic effects that could affect the result. We obtained Ga from the MARS recoil spectrometer by bombarding a cooled hydrogen gas target with Zn at 42A MeV. Special care was taken for the optimization of the Ga beam from MARS in order to minimize the impurities. At the exit of MARS, the beam was degraded and then implanted in the aluminized mylar tape of our fast tape-transport system. The short halflife of Ga (t1/2 = 116 ms) made it impractical to use our normal reel-to-reel tape system; instead, we employed a closed single-loop path design, similar to that described in [1], which removed the need for frequent tape rewinds. The Ga was collected on tape for 0.25 s; then the beam was turned off and the collected activity was moved within 135 ms in the center of a 4π proportional gas counter placed in a low background region. The counter signals were then multiscaled for 3.00 s and a decay spectrum consisting of 250 channels was recorded. About 10 separate decay spectra, one from each collect/move/detect cycle, were recorded. To allow for tests of possible systematic errors, the data were split into separate runs typically of over a thousand cycles each. The detector bias, discriminator threshold, time interval per channel and the setting for the dominant deadtime were changed sequentially from run to run. In analysis, each run underwent a presorting procedure that removed the cycles in which less than 25 decay events were recorded in the 4π detector, and the cycles for which the ratio of the recorded β-decays versus the number of deposited nuclei was anomalous, indicating either high noise (too many events) or bad tape positioning (too few events). Runs passing the pre-sort procedure with less than 50 valid cycles were nevertheless removed entirely as not having statistical significance. About 3 million events, in total, survived this procedure. The spectrum for the data subset with a timing of 12 ms per channel is presented in Fig. 1. To achieve a high-precision half-life measurement we require a very good knowledge
منابع مشابه
KINETICS AND MECHANISM OF AERIAL OXIDATION OF HYDROQUINONE IN A DEVELOPER SOLUTION AND DETERMINATION OF DEVELOPER'S HALF-LIFE AT 20°C
The aerial oxidation of hydroquinone in a freshly prepared developer solution at 20°C has been studied through the measurement of concentration changes by a spectrophotometric method. The concentration of consumed hydroquinone is directly proportional to time, and the equation tIl2 = C, / 0.0786 was obtained to calculate the half-life of the developer. In this equation, the half-life is in ...
متن کاملUltrasonographic fetal scapular length measurement for assessment of gestational age
one of the major goals of antenatal care is estimation of gestational age.the most widely used parameters for evaluation of fetal growth are biparietal diameter (BPD),femoral length (FL) and adbominal circumference (AC).to determine the value of prenatal ultrasonographic scapula measurements for fetal growth and gesattional age a prospective ultrasonographic cross-sectional study was conducted ...
متن کاملProcessing Digital Image for Measurement of Crack Dimensions in Concrete
The elements of the concrete structure are most frequently affected by cracking. Crack detection is essential to ensure safety and performance during its service life. Cracks do not have a regular shape, in order to achieve the exact dimensions of the crack; the general mathematical formulae are by no means applicable. The authors have proposed a new method which aims to measure the crack dimen...
متن کاملFetal Adrenal Gland in the Second Half of Gestation: Morphometrical Assessment with 3.0T Post-Mortem MRI
BACKGROUND The morphometry of fetal adrenal gland is rarely described with MRI of high magnetic field. The purpose of this study is to assess the normal fetal adrenal gland length (AL), width (AW), height (AH), surface area (AS) and volume (AV) in the second half of gestation with 3.0T post-mortem MRI. METHODS AND FINDINGS Fifty-two fetal specimens of 23-40 weeks gestational age (GA) were sca...
متن کامل