Ventricular tachycardia detection using bipolar electrogram analysis is site specific.
نویسندگان
چکیده
While algorithms for bipolar intraventricular electrogram analysis have potential use in complementing rate criteria for ventricular tachycardia (VT) detection by implantable antitachycardia devices, the sensitivity of such algorithms to the intracavitary site of electrogram detection has not been determined. In this study, unfiltered (1-500 Hz) electrograms were recorded from a bipolar electrode catheter initially positioned at the right ventricular (RV) apex (site 1) of 12 patients during sinus rhythm (SR1) and during induced monomorphic VT (VT1). Sinus rhythm (SR2) and the identical VT (VT2) were recorded a second time after repositioning the same electrode catheter within the RV apex (site 2) 7-44 mm (mean +/- SD = 15 +/- 10) from its original site. The data were digitized at 1,000 Hz. Templates from SR1 and SR2, respectively, were compared subsequently with individual intraventricular electrograms from 15-25 sec passages of SR1 and VT1 and SR2 and VT2, respectively, using correlation waveform analysis. At site 1, the mean patient correlation coefficient ranged from 0.982-0.998 during SR1 and 0.062-0.975 during VT1. At site 2, the mean patient correlation coefficient ranged from 0.995-0.998 during SR2 and 0.113-0.983 during VT2. Using a correlation threshold of 0.9, VT was differentiated from SR in 11/12 patients (91%) overall: 8/12 patients (67%) at site 1, 9/12 patients (75%) at site 2, and 6/12 patients (50%) at both sites. Thus, while discrimination of VT from SR is feasible with morphological analysis of bipolar right ventricular intracavitary electrograms, the accuracy of bipolar intraventricular electrogram analysis may depend upon intracavitary electrode location in selected patients.
منابع مشابه
Identification of ventricular tachycardia using intracardiac electrograms: a comparison of unipolar versus bipolar waveform analysis.
Implantable antitachycardia devices suffer a high false-positive rate of delivery of therapy because current detection schemes based upon ventricular rate and rate variations are excessively sensitive at the cost of specificity. Several methods have been proposed for providing complementary information derived from morphologic analysis of intraventricular electrograms in order to increase speci...
متن کاملA fourth criterion for transient entrainment: the electrogram equivalent of progressive fusion.
Prior data pertaining to transient entrainment and associated phenomena have been best explained by pacing capture of a reentrant circuit. On this basis, we hypothesized that rapid pacing from a single site of two different constant pacing rates could constantly capture an appropriately selected bipolar electrogram recording site from one direction with a constant stimulus-to-electrogram interv...
متن کاملParoxysmal bundle branch block of supraventricular origin: a possible source of misdiagnosis in detecting ventricular tachycardia using time domain analyses of intraventricular electrograms.
Current implantable antitachycardia devices use several methods for differentiating sinus rhythm (SR) from supraventricular tachycardia (SVT) or ventricular tachycardia (VT). These methods include sustained high rate, the rate of onset, changes in cycle length, and sudden onset. Additional methods for detecting VT include techniques based upon ventricular electrogram morphology. The morphologic...
متن کاملNovel algorithmic methods in mapping of atrial and ventricular tachycardia.
BACKGROUND Conventional methods to assess local activation time (LAT) detect the peak of the bipolar electrogram (B-LATPeak) or the maximal negative slope of the unipolar electrogram (U-LATSlope). We evaluated 3 novel methods to assess LAT: onset (B-LATOnset) and center of mass (B-LATCoM) of bipolar electrogram, and maximal negative slope of unipolar electrogram within a predefined bipolar wind...
متن کاملRadiofrequency Catheter Ablation with the Use of a Noncontact Mapping System for Ventricular Tachycardia Originating from the Aortic Sinus Cusp —A Case Report—
Here we present a 15-year old female in whom an idiopathic ventricular tachycardia (VT) originating from the left aortic sinus cusp was eliminated by radiofrequency catheter ablation (RFCA) under navigation using a noncontact mapping system (NCM). The dynamic activation map constructed with the NCM clearly identified a VT focus in the left aortic sinus cusp, from which the activation spread out...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Pacing and clinical electrophysiology : PACE
دوره 15 11 Pt 2 شماره
صفحات -
تاریخ انتشار 1992