On-line preconcentration system using mini-column packed with a chelating resin for the characterization of seasonal variations of trace elements in seawater by ICP-MS and ICP-AES.
نویسندگان
چکیده
An on-line column preconcentration technique coupled with inductively coupled plasma-mass spectrometry (ICP-MS) and -atomic emission spectrometry (ICP-AES) was developed using a mini-column (ca. 3 mm i.d., 40 mm length), that was packed with chelating resin (0.2 g) of iminodiacetic acid groups, Muromac A-1. After the preconcentration step, the column was washed with ammonium acetate buffer (pH 5.5) and water to remove major elements, such as Ca and Mg, and then eluted with 4 ml of 2 mol l(-1) nitric acid. Eleven trace elements (Al, V, Fe, Co, Ni, Cu, Zn, Cd, Pb, Th and U) in seawater were determined by ICP-MS/AES. Recoveries for most of the elements tested were over 90%, although those for Al, V and Th were around 70%. The accuracy of the proposed method was evaluated by analyzing a standard reference material of seawater (NASS-4, NRC Canada). The values of Fe, Co, Ni, Cu, Zn, Cd and Pb obtained with the present method showed good agreement with the certified values as judged from the standard deviation. The method was successfully applied to characterize seasonal variations of trace elements in deep seawater (DSW) and surface seawater (SSW). In addition, no serious decrease in analytical performance of the present column system was observed during the experimental period of about 1 year.
منابع مشابه
Synthesis of cross-linked chitosan modified with the glycine moiety for the collection/concentration of bismuth in aquatic samples for ICP-MS determination.
A chelating resin, cross-linked chitosan modified with the glycine moiety (glycine-type chitosan resin), was developed for the collection and concentration of bismuth in aquatic samples for ICP-MS measurements. The adsorption behavior of bismuth and 55 elements on glycine-type chitosan resin was systematically examined by passing a sample solution containing 56 elements through a mini-column pa...
متن کاملSpeciation of chromium in seawater by ICP-AES with dual mini-columns containing chelating resin.
A method for the preconcentration and speciation of chromium in seawater was developed. On-line preconcentration and determination were carried out by using inductively coupled plasma atomic emission spectrometry (ICP-AES) with dual mini-columns containing a chelating resin. In this system, Cr(III) was collected on the first column. The effluent containing residual chromium from the first colum...
متن کاملTrace elements determination in seawater by ICP-MS with on-line pre-concentration on a Chelex-100 column using a ‘standard’ instrument setup.
Trace element determination in seawater is analytically challenging due to the typically very low concentrations of the trace elements and the potential interference of the salt matrix. A common way to address the challenge is to pre-concentrate the trace elements on a chelating resin, then rinse the matrix elements from the resin and subsequently elute and detect the trace elements using induc...
متن کاملApplication of iminodiacetate chelating resin muromac A-1 in on-line preconcentration and inductively coupled plasma optical emission spectroscopy determination of trace elements in natural waters
On-line system incorporating a microcolumn of Muromac A-1 resin was used for the developing of method for preconcentration of trace elements followed by inductively coupled plasma (ICP) atomic emission spectrometry determination. A chelating type ion exchange resin has been characterized regarding the sorption and subsequent elution of 24 elements, aiming to their preconcentration from water sa...
متن کاملOn-line preconcentration method for the determination of trace metals in water samples using a fully automated pretreatment system coupled with ICP-AES.
An automated on-line sample-preparation method using a computer-controlled pretreatment system (Auto-Pret AES system) coupled with ICP-AES was developed. In this work, an iminodiacetate chelating resin, packed in a mini-column and installed in the system was employed for the collection/concentration of 13 trace metals, including such toxic metals as Be, Cd, Cr, Cu and Pb. The limits of detectio...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical sciences : the international journal of the Japan Society for Analytical Chemistry
دوره 22 9 شماره
صفحات -
تاریخ انتشار 2006