Development of X-ray TV M-mode and reconstructed ultrasound M-mode methods for investigating tongue movement during swallowing in humans.

نویسندگان

  • S Kawashima
  • Y Takahashi
  • N Niikuni
  • K Kanazawa
  • I Nakajima
  • M Akasaka
  • Y Arai
  • K Hashimoto
  • K Shinoda
چکیده

There were two purposes of this study. The first purpose was to introduce the "X-ray TV M-mode waveform" which is reconstructed from sequential X-ray TV images and the "reconstructed ultrasound M-mode waveform" which is delivered from ultrasound B-mode images. The second purpose was to evaluate the usefulness of these two types of waveforms in the investigation of tongue movement during swallowing. The instrument system employed in this study consisted of ultrasound and X-ray TV synchronized by a time marker. After the X-ray images and ultrasound B-mode images were recorded on an optical disk, X-ray TV M-mode waveform and ultrasound M-mode waveform were reconstructed using an MC 68030/OS-9 computer. No significant differences in quality of images were observed between the X-ray TV M-mode waveform and the reconstructed ultrasound M-mode waveform. Therefore, both waveforms of the X-ray TV M-mode and the reconstructed ultrasound M-mode are equally useful in measuring tongue movement.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Application of B+M-Mode Ultrasonography in Assessing Deglutitive Tongue Movements in Healthy Adults

BACKGROUND The purpose of this study was to evaluate tongue movements during swallowing in healthy adults using the B+M-mode ultrasonography, and to determine a common feature in the M-mode traces for quantitative measurement and individual comparison of tongue movements. MATERIAL AND METHODS Ninety healthy subjects were divided into 3 groups according to age (20-39, 40-59, and 60-80 years). ...

متن کامل

Comparison between M-Mode and Doppler echocardiography in diagnosis

Introduction: Patent ductus arteriosus (PDA) is the persistence of a normal fetal structure between left pulmonary artery and descending aorta. Persistence of this fetal structure beyond 10 days of life is considered abnormal. In this study we compared M-Mode and Doppler echocardiography in diagnosis of PDA in children at Aliasghar Hospital in Zahedan and Children hospital in Bandar Abbas for...

متن کامل

Usability assessment of cone beam computed tomography with a full-fan mode bowtie filter compared to that with a half-fan mode bowtie filter

Background: In intensity modulated radiation therapy, cone beam computed tomography (CT) has been used to evaluate patients prior to treatment. This study conducted a comparative evaluation of the image reconstruction ability of the clinically used half-fan bowtie filter and the full-fan bowtie filter. Materals and Methods: A CT simulation marker was inserted inside a human phantom, and the pel...

متن کامل

Adaptation of Tongue Function in Surgically Treated Cleft Patients - Motion Mode Ultrasonographic Study

Aims & Objectives: To assess the functional efficiency and adaptation of tongue musculature in surgically treated cleft Patients by measuring the amplitude of contraction, fractional shortening of tongue musculature and to compare the changes in functional adaptive efficiency following surgery using m-mode ultrasonography. Methods: The study was carried out on 90 cleft patients both with comple...

متن کامل

On the development of a sliding mode observer-based fault diagnosis scheme for a wind turbine benchmark model

This paper addresses the design of an observer-based fault diagnosis scheme, which is applied to some of the sensors and actuators of a wind turbine benchmark model. The methodology is based on a modified sliding mode observer (SMO) that allows accurate reconstruction of multiple sensor or actuator faults occurring simultaneously. The faults are reconstructed using the equivalent output err...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of oral science

دوره 41 1  شماره 

صفحات  -

تاریخ انتشار 1999