Probing the intracellular organic matters released from the photocatalytic inactivation of bacteria using fractionation procedure and excitation-emission-matrix fluorescence.
نویسندگان
چکیده
Photocatalysis provides a "green" and effective strategy for water disinfection. During the photocatalytic disinfection process, intracellular organic matter (IOM) from bacterial cells may be released into the bulk solution. In this study, the role of released IOM in the photocatalytic bacterial inactivation was investigated by fractionation procedure and fluorescence excitation-emission-matrix (EEM) combined with parallel factor analysis (PARAFAC) approaches. The normal bacterial cells treated by TiO2-UVA in the presence and absence with fractionated IOM results implied that the released IOM would be either absorbed on the surface of the photocatalysts or reacted by the photo-generated reactive species, and thereby affecting the kinetics of photocatalytic bacterial inactivation. Fluorescence EEM-PARAFAC results showed that two components (C1 and C3) associated with tryptophan- and tyrosine-like proteins were released. While another two components (C2 and C4) were the oxidation products, and their intensities were found to negatively correlate with those of C1 and C3, respectively. Microtox® test results indicated that toxicity occurred during the photocatalytic bacterial inactivation process. The toxicity was found to decrease after the bacteria were completely inactivated, and completely removed if provided a sufficient reaction time. Of particular interest is that a significant high linear correlation was observed between the toxicity and the maximum fluorescence intensity of C4. The results and information obtained in this study will be important for further developing photocatalysis in water/wastewater disinfection.
منابع مشابه
Organic matter from biofilter nitrification by high performance size exclusion chromatography and fluorescence excitation-emission matrix
A combination of high performance size exclusion chromatography with organic carbon detector and ultraviolet detector coupled with peak-fitting technique and fluorescence excitation-emission matrix spectrometry applied fluorescence regional integration method was conducted to determine the characteristics of organic matter during nitrification. The batch scale of bionet nitrification without or...
متن کاملSimultaneous Determination of Ibuprofen and Caffeine in Urine Samples by Combining MCR-ALS and Excitation-emission Data
Second order advantage of excitation-emission fluorescence matrix was applied for the simultaneous determination of ibuprofen and caffeine. The proposed method is based on the measurement of the native fluorescence and recording emission spectra of ibuprofen and caffeine in different excitation wavelengths. The mixture of these compounds was resolved by multivariate curve resolution coupled wit...
متن کاملCombined Unfolded Principal Component Analysis and Artificial Neural Network for Determination of Ibuprofen in Human Serum by Three-Dimensional Excitation–Emission Matrix Fluorescence Spectroscopy
This study describes a simple and rapid approach of monitoring ibuprofen (IBP). Unfolded principal component analysis-artificial neural network (UPCA-ANN) and excitation-emission spectra resulted from spectrofluorimetry method were combined to develop new model in the determination of IBF in human serum samples. Fluorescence landscapes with excitation wavelengths from 235 to 265 nm and emission...
متن کاملCombined Unfolded Principal Component Analysis and Artificial Neural Network for Determination of Ibuprofen in Human Serum by Three-Dimensional Excitation–Emission Matrix Fluorescence Spectroscopy
This study describes a simple and rapid approach of monitoring ibuprofen (IBP). Unfolded principal component analysis-artificial neural network (UPCA-ANN) and excitation-emission spectra resulted from spectrofluorimetry method were combined to develop new model in the determination of IBF in human serum samples. Fluorescence landscapes with excitation wavelengths from 235 to 265 nm and emission...
متن کاملCoupling Second-Order Excitation-Emission Spectrofluorimetric Data with Standard Addition method to Quantify Carvedilol in Real Samples
Prediction using pure standards is expected to be biased whenever the slope of the calibration is affected by the presence of sample matrix. Moreover, in the presence of unknown spectral interferents, first-order algorithms like partial least squares cannot be used. In this study, a method for determination of carvedilol (CAR) in tablet and urine samples is proposed by excitation-emission fluor...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Water research
دوره 110 شماره
صفحات -
تاریخ انتشار 2017