Silver-enhanced radial immunodiffusion assay

نویسنده

  • Beverly Paigen
چکیده

Silver-staining of immunoprecipitates extends the sensitivity of the radial immunodiffusion assay by tenfold. This modification permits the quantification of apolipoproteins A-1, A-11, C, and E at levels of 0.2-1.0 mg/d in plasma samples at a sensitivity threshold of 10 ng. The silver-enhanced radial immunodiffusion method is readily adapted from the standard method, simple and inexpensive to perform, and does not require costly instrumentation. These advantages make the modified RID assay an attractive alternative to other forms of immunoassayIshida, B. Y., and B. Paigen. Silver-enhanced radial immunodiffusion assay of plasma apolipoproteins. J. Lipid Res. 1992. 33: 1073-1078.

منابع مشابه

A Simple Radial Immunodiffusion Method for Assay of f32-Microglobulin in Serum

In this method for clinical measurement of /32-microglobulin, a 10 g/L agarose gel containing anti-/32-microglobulin is used, with subsequent staining with Coomassie Blue. Although the method is slow (requiring 30 h), it is inexpensive, reliable, and accurate over the range of ito 10 mg/L, and is useful in the determination of f32-microglobulin in serum and cerebrospinal fluid. A modified proce...

متن کامل

Evaluation of Haemagglutinin Content by RP-HPLC to Generate Pandemic Influenza Vaccine

The potency of influenza vaccine is determined based on its hemagglutinin (HA) content. In general, single radial immunodiffusion (SRID) assay has been utilized as the standard method to measure HA content. However, preparation of reagents for SRID such as antigen and antibody takes approximately 2~3 months, which causes delays in the development of influenza vaccine. Therefore, quantification ...

متن کامل

Enhanced-latex-agglutination assay for C-reactive protein in serum, with use of a centrifugal analyzer.

This is an improved assay of C-reactive protein in serum, for use with the Baker "Encore" centrifugal analyzer. Features of this assay include: 250-specimen throughput per hour, within-batch CV 2.2%, between-batch CV 2.7%, no antigen-excess problems up to 1000 mg/L, negligible interference from rheumatoid factor, and good correlation (r = 0.99) with radial immunodiffusion. The method is inexpen...

متن کامل

Concentrations of plasma immunoglobulins in the dog as determined by laser nephelometry. Comparison with radial immunodiffusion and enzyme-linked immunosorbent assay.

Concentrations of immunoglobulins were determined by laser nephelometry and, for comparison, by single radial immunodiffusion assay and a sandwich enzyme-linked immunosorbent assay (ELISA) in plasma samples of normal dogs. Correlation between methods was high, although the mean IgM concentrations determined by laser nephelometry were significantly higher than those determined by the single radi...

متن کامل

Three immunoassay methods evaluated for quantifying prealbumin (transthyretin) in serum.

We developed an immunoturbidimetric assay for prealbumin on the Cobas Bio centrifugal analyzer and compared results from this assay with those from a rate nephelometric assay (Beckman Instruments Inc.) and a radial immunodiffusion kit (Behring Diagnostics). All three assays were evaluated for precision, linearity, and correlation to each other for analysis of sera from pediatric patients. All a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

متن کامل
عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002