SU-D-217BCD-04: How Do We Know How Low Can We Go in Lung Cancer Screening CT?

نویسندگان

  • L Chen
  • A Sykes
  • E Jensen
  • P Eiken
  • L Yu
  • S Leng
  • C McCollough
چکیده

PURPOSE To demonstrate a technique for determining the acceptable radiation dose level for lung cancer screening CT. METHODS 20 patients who underwent a clinically indicated routine chest CT scan with 120 kV and 180 quality reference mAs were enrolled in this IRB approved study. Automatic exposure control was used to adjust for patient size. Scanner output, as expressed in CTDIvol, varied accordingly (mean=16.8 mGy, range=7.6 to 26.6 mGy). A previously validated noise insertion software tool developed in our lab was used to simulate scans acquired with reduced dose levels (12.5%, 25%, 50% of the original dose level). Images reconstructed from the same raw data but at the original and simulated, reduced dose levels were randomized and blindly reviewed by three thoracic radiologists. Lung and soft tissue regions were graded for two different imaging tasks: 1) routine diagnostic CT exam of the chest and 2) screening exam of the chest for lung cancer. A 5 point scale was used to rate each exam for each task (1=too noisy, significantly impacted confidence to 5=excellent quality, excellent confidence). Exams were considered acceptable when at least two of the three radiologists gave a score of 3 or higher. The percentage of patients meeting this definition of acceptable was calculated for each imaging task, dose level, and tissue type (lung or soft tissue). RESULTS The percentages of exams considered acceptable for the purpose of lung cancer screening were 90%, 100%, 100%, 100% (lung tissue) and 85%, 100%, 100%, 100% (soft tissue) at 12.5%, 25%, 50% and 100% of original dose level. For the purpose of routine diagnostic chest CT, the percentage of acceptable exams were 75%, 95%, 100%, 100% (lung tissue) and 35%, 85%, 90%, 100% (soft tissue) at 12.5%, 25%, 50% and 100% of original dose level. CONCLUSIONS At 25% of the dose used for routine diagnostic chest CT at our institution, acceptable image quality for the purpose of CT screening for lung cancer was achieved in 100% of the evaluated cases. This factor of 4 in dose reduction relative to routine chest exams is similar to what was used in the NLST trial.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Satisfaction Function in Present Undesirable Factors

Data Envelopment Analysis (DEA) is an efficient method to perform evaluation of units. In DEA we try to evaluate units with undesirable factors in input & outputs by satisfaction function, testing some models. On the other hand benefiting this concept, we can identify non-efficient units. Also we can recognize why these units are inefficient and calculate the reason of their inefficiency and ho...

متن کامل

Welcome to virosphere

Viruses may seem alien, but they are the most abundant and, arguably, the most important organisms on Earth. They are found just about everywhere, from oceans and forests to the people around you and, of course, in and on you as well. This world of strange, quasi-living things has been dubbed the virosphere, and it is a mysterious one – we know less about viruses than any other life form. But t...

متن کامل

Seventy FDG-PET/CT cases in which nuclear medicine physicians suspected lymphoma: How reliable are we?

Objective(s): To validate the reliability of nuclear medicine physicians in diagnosing lymphoma using positron emission tomography/computed tomography using 2-deoxy-2-[18F]fluoro-D-glucose (FDG-PET/CT) and to determine findings that reliably suggest lymphoma.Methods: Seventy patients suspected of having lymphoma using FDG-PET/CT were enrolled in this retrospective study. Two nuclear medicine ph...

متن کامل

Both F-18 FDG-avidity and Malignant Shape of Cervical Lymph Nodes on PET/CT after Total Thyroidectomy Predict Resistance to High-dose I-131 Therapy in Patients with Papillary Thyroid Cancer

Objective: Resistance of metastatic lymph nodes (LNs) to high dose I-131 therapy is associated with high morbidity in patients with differentiated thyroid cancer. We evaluated the role of F-18 FDG PET/CT in the prediction of resistance to high dose I-131 therapy in patients with papillary thyroid cancer. Methods: The subjects were 307 patients who underwent total or near total thyroidectomy fol...

متن کامل

تخمین هزینه بهره وری غربالگری سرطان ریه در ایران توسط تصویر برداری سی تی اسکن دوز پایین با در نظر گرفتن تعداد تشخیص های زودهنگام

Introduction: Lung cancer is the most common and most deadly cancer in most of countries of the world. One of the most significant problems with this cancer is the lack of accurate and specific statistics about the prevalence and mortality rate in Iran. Results of cancer registry program in 2008 in Iran indicated a low incidence rate of lung cancer. However, these statistics...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 39 6Part3  شماره 

صفحات  -

تاریخ انتشار 2012