Safety of Percutaneous Patent Ductus Arteriosus Closure: An Unselected Multicenter Population Experience

نویسندگان

  • Howaida G. El‐Said
  • Andras Bratincsak
  • Susan R. Foerster
  • Joshua J. Murphy
  • Julie Vincent
  • Ralf Holzer
  • Diego Porras
  • John Moore
  • Lisa Bergersen
چکیده

BACKGROUND The technique and safety of transcatheter patent ductus arteriosus (PDA) closure have evolved during the past 20 years. We sought to report a multicenter experience of PDA closure with a focus on the rate of adverse events (AE) and a review of institutional practice differences. METHODS AND RESULTS Outcome data on transcatheter PDA closure were collected at 8 centers prospectively using a multicenter registry (Congenital Cardiac Catheterization Project on Outcome Registry). Between February 2007 and June 2010, 496 PDA closures were recorded using a device in 338 (68%) or coils in 158 (32%). Most patients had an isolated PDA (90%). Fifty percent of patients were between 6 months and 3 years old, with only 40 patients (8%) <6 months old. Median minimum PDA diameter was 2.5 mm (range 1 to 12 mm; IQR 2 to 3 mm) for device closure and 1 mm (range 0.5 to 6 mm; IQR 1 to 2 mm) for coil closure (P<0.001). A device rather than coil was used in patients <3 years, weight <11 kg, and with a PDA minimum diameter >2 mm (all P<0.001). Three of 8 centers exclusively used a device for PDAs with a diameter >1.5 mm. In 9% of cases (n=46), an AE occurred; however, only 11 (2%) were classified as high severity. Younger age was associated with a higher AE rate. Coil-related AEs were more common than device-related AEs (10% versus 2%, P<0.001). CONCLUSIONS PDA closure in the present era has a very low rate of complications, although these are higher in younger children. Technical intervention-related events were more common in coil procedures compared with device procedures. For PDAs ≤2.5 mm in diameter, institutional differences in preference for device versus coil exist.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transcatheter closure of the patent ductus arteriosus using an Amplatzer duct occluder in adults.

Patent ductus arteriosus (PDA) is a congenital heart disease that frequently escapes detection until the patient reaches adulthood. Percutaneous closure of the PDA has been established as a safe alternative to surgery, the Amplatzer duct occluder (ADO) is a new device that has been recently reported in paediatric patients. Our initial experience with an of ADO in an adult population appears to ...

متن کامل

Percutaneous closure of a post-traumatic ventricular septal defect with a patent ductus arteriosus occluder

OBJECTIVE Ventricular septal defects resulting from post-traumatic cardiac injury are very rare. Percutaneous closure has emerged as a method for treating this disorder. We wish to report our experience in three patients who underwent percutaneous closure of a post-traumatic ventricular septal defect with a patent ductus arteriosus occluder. METHODS We treated three patients with post-traumat...

متن کامل

Intravenous Paracetamol and Patent Ductus Arteriosus Closure

Background: Standard medical treatments for patent ductus arteriosus (PDA) closure are, including indomethacin/ibuprofen and surgical ligation. Nowadays, a new strategy to close PDA is the use of paracetamol. The present study aimed to describe the use of intravenous (IV) paracetamol for PDA closure in neonates who present a contraindication to ibuprofen or ibuprofen failure with no possibility...

متن کامل

Patent ductus arteriosus in a lamb: A case report

Patent ductus arteriosus (PDA) is a persistent patency of a vessel normally present in the fetus that connects the pulmonary arterial system to the aorta. The ductus arteriosus fails to close at birth when breathing commences and placental blood circulation is removed. Closure of the ductus arteriosus arises in response to decline pulmonary vascular resistance and increased systemic vascular re...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2013