Intrarenal pressures generated during deployment of various antiretropulsion devices in an ex vivo porcine model.

نویسندگان

  • Lara K Suh
  • Michael B Rothberg
  • Jaime Landman
  • Hiroshi Katsumi
  • Mantu Gupta
چکیده

INTRODUCTION Pressurized saline irrigation is commonly used during ureteroscopy, which can cause an increase in intrarenal pressure leading to postoperative pain, sepsis, and renal injury due to pyelovenous and pyelolymphatic backflow. To prevent retrograde stone migration during ureteroscopic lithotripsy, antiretropulsion devices can be deployed, which may or may not protect the kidney against high intrarenal pressures. This study compares the intrarenal pressures generated during the use of two antiretropulsion devices in an ex vivo porcine model. MATERIALS AND METHODS Using an ex vivo porcine model of the urinary system, flexible ureteroscopy was performed at the proximal, mid, and distal ureter. Intrarenal pressures were measured in the absence and presence of a coil-based antiretropulsion device and a multifold film-based device. Intrarenal pressure measurements were obtained while using saline irrigation at a gravity of 84 cm H(2)O and pressures of 150 and 300 mm Hg. RESULTS The deployment of a coil device resulted in a significant increase in intrarenal pressures during ureteroscopy with pressurized irrigation when compared with intrarenal pressures without a device. The use of a multifold film device that occluded the ureter during ureteroscopy resulted in a decrease in intrarenal pressures at an irrigation pressure of 300 mm Hg when compared with pressures without a device. In the remaining configurations, the intrarenal pressures were only minimally elevated. When comparing the two devices to each other, the multifold film device had significantly lower intrarenal pressures at each configuration. This has potential implications in preventing renal injury and/or sepsis during ureteroscopy. CONCLUSION The use of a multifold film antiretropulsion device during ureteroscopy with high-pressure irrigation can potentially protect the kidney from elevated intrarenal pressures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intrarenal pressure and irrigation flow with commonly used ureteric access sheaths and instruments

INTRODUCTION Flexible ureterorenoscopy is becoming a first-line treatment for many intrarenal stones. Ureteric access sheaths are commonly used to aid access, stone removal and reduce intrarenal pressure. We evaluated the effects of two commonly used access sheaths on irrigation flow and intrarenal pressure during flexible ureterorenoscopy. We measured the effect of scope instrumentation on flo...

متن کامل

Comparison of Peditrol irrigation device and common methods of irrigation.

BACKGROUND AND PURPOSE The Peditrol is a novel hands-free irrigation device that delivers a bolus of irrigant through the ureteroscope when the foot pedal is deployed. The purpose of this study was to compare the flow and pressures created by the Peditrol with those of commonly used methods of irrigation. MATERIALS AND METHODS Flows through a flexible 6.9F Olympus ureteroscope (F-URS) and a 7...

متن کامل

Development of Fast Dissolving Sublingual Wafers of Promethazine Hydrochloride

Promethazine hydrochloride, a 5-HT3 antagonist is a powerful antiemetic drug with an oral bioavailability of 25% due to extensive hepatic first pass metabolism and is extremely bitter in taste. To overcome the above draw backs, the present study was carried out to formulate and evaluate fast dissolving taste masked wafers of Promethazine hydrochloride for sublingual administration. Taste maskin...

متن کامل

Novel Sensor-Enabled Ex Vivo Bioreactor: A New Approach towards Physiological Parameters and Porcine Artery Viability

The aim of the present work is to design and construct an ex vivo bioreactor system to assess the real time viability of vascular tissue. Porcine carotid artery as a model tissue was used in the ex vivo bioreactor setup to monitor its viability under physiological conditions such as oxygen, pressure, temperature, and flow. The real time tissue viability was evaluated by monitoring tissue metabo...

متن کامل

The effect of acid modification of porcine mucin on its drug release and skin permeation properties in insulin transdermal patches

The study aimed at determining the effect of acid modified porcine mucin powder on the release and permeation of insulin in transdermal patches. Various batches of insulin patches were prepared by solvent casting method using polysorbate 80 as emulsifying agent and acid treated and untreated mucin powders as base. The patches were evaluated for their physical properties, folding endurance, moi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of endourology

دوره 24 7  شماره 

صفحات  -

تاریخ انتشار 2010