Imaging interferometers for analysis of Thomson scattered spectra.
نویسندگان
چکیده
Polarization interferometers have some potential efficiency advantages for imaging Thomson scattering spectral analysis. In this article we present a number of designs for high-efficiency imaging polarization interferometers for Thomson scattering spectral analysis. The use of high-efficiency crystal polarizing beamsplitters (both displacement and angle) results in low-loss complementary passbands (no edge losses), simple imaging systems, and wide field of view. The efficiency and relative merits of both multiple-filter and dispersive-type configurations are being assessed before installation on the JT-60U ruby-laser Thomson scattering system. Light is transferred from the viewing port via a linear array of optical fiber bundles which will be imaged through the interferometer onto the photocathode of an intensified charge coupled device camera. Because of the broadband nature of the Thomson light, the optical delays required to Fourier analyze the spectrum are quite small. This leads to compact multicolor or dispersive systems based on combinations of Wollaston and Savart splitters and traditional waveplates.
منابع مشابه
Application of polarization interferometers for Thomson scattering
Wide field-of-view, high transparency birefringent filters (essentially fixed delay interferometers) are proposed for incoherent Thomson scattering measurements of the temperature and density of plasma free electrons. For thermal electrons, the optical coherence of the Thomson scattered light at an appropriately chosen optical path delay, is a unique function of the electron temperature and den...
متن کاملEnergy window setting for optimum Tl-201 cardiac imaging [Persian]
Introduction: Poor sensitivity and poor signal to noise ratio because of low injected thallium dose and presence of scattered photons are the main problems in using thallium in scintigraphic imaging of the heart. Scattered photons are the main cause of degrading the contrast and resolution in SPECT imaging that result in error in quantification. Thallium decay is ve...
متن کاملCommissioning activities and first results from the collective Thomson scattering diagnostic on ASDEX Upgrade (invited).
The collective Thomson scattering (CTS) diagnostic installed on ASDEX Upgrade uses millimeter waves generated by the newly installed 1 MW dual frequency gyrotron as probing radiation at 105 GHz. It measures backscattered radiation with a heterodyne receiver having 50 channels (between 100 and 110 GHz) to resolve the one-dimensional velocity distribution of the confined fast ions. The steerable ...
متن کاملImpact of Photon Spectra on the Sensitivity of Polymer Gel Dosimetry by X-Ray Computed Tomography
Introduction: The purpose of the current study was to investigate the effect of X-ray spectra on the sensitivity of a polymer gel dosimeter imaged with a conventional computed tomography (CT) scanner. Material and Methods: The whole process of CT imaging of an irradiated polymer gel was simulated by MCNPX Monte Carlo (MC) code. The imaging of polyacrylamide gel was accomplished by means of a co...
متن کاملAn Interferometry Imaging Beauty Contest
We present a formal comparison of the performance of algorithms used for synthesis imaging with optical/infrared long-baseline interferometers. Five different algorithms are evaluated based on their performance with simulated test data. Each set of test data is formatted in the OI-FITS format. The data are calibrated power spectra and bispectra measured with an array intended to be typical of e...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Review of scientific instruments
دوره 79 10 شماره
صفحات -
تاریخ انتشار 2008