Implant surface morphology and primary stability: is there a connection?

نویسندگان

  • Fawad Javed
  • Khalid Almas
  • Roberto Crespi
  • George E Romanos
چکیده

PURPOSE The aim was to review the influence of surface morphology on the primary stability of dental implants. METHODS MEDLINE-PubMed databases were explored from 1991 up to and including April 2010 using different combinations of the following terms: "dental," "implant surface roughness," "immediate loading," "initial stability," "primary stability," and "osseointegration." Articles published only in English language were included and hand searching was also performed. Letters to the Editor and unpublished data were excluded. RESULTS Ten studies (three clinical and seven experimental) were included according to the search databases. In six studies (three experimental and three clinical), the implant stability was measured at least after 4 weeks after implant insertion; and primary implant stability was recorded in four experimental studies, using the insertion and removal torque tests and resonance frequency analysis using implant stability quotient values. CONCLUSION Rough-surfaced implants have significantly higher success rates compared with dental implants with smooth surfaces; however, the question "Is there a connection between implant surface roughness (microdesign) and primary stability?" remains unanswered.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Immediate loading in dental implants ( A literature review )

Immediate loading in dental implants ( A literature review ) Dr. Seyedan K.,1 Dr. Hafezeqoran A.,2 Dr. Sazgara H.3 1Assistant Professor, Department of Prosthodentists,Dental School Shahid Beheshti University of Medical Sciences,Tehran, Iran.2Dentist, Post Graduate Student, Department of Prosthodontics, Dental School, Shahid Beheshti University of Medical Sciences, Tehran-Iran.3Associate Profess...

متن کامل

Implant Stability - Measuring Devices and Randomized Clinical Trial for ISQ Value Change Pattern Measured from Two Different Directions by Magnetic RFA

Implant stability plays a critical role for successful osseointegration, which has been viewed as a direct structural and functional connection existing between bone and the surface of a load-carrying implant(Bränemark, et al. 1977, Sennerby & Roos 1998). Achievement and maintenance of implant stability are prerequisites for successful clinical outcome(Sennerby & Meredith 2008). Therefore, meas...

متن کامل

Effect of Abutment Connection Type and Cyclic Loading on Removal Torque Value

Background and Aim: Maintaining the primary torque of the abutment screw is a common problem related to implant-supported restorations; a failure in this respect often leads to screw loosening. The abutment screw plays a critical role in the long-term stability of restorations. This study aimed to assess the effect of two abutment connection types with and without cyclic loading on removal torq...

متن کامل

Macroscopic and microscopic evaluation of a new implant design supporting immediately loaded full arch rehabilitation.

The purpose of this study is to evaluate macroscopic and microscopic appearance of a new implant design, with particular emphasis given to the type of prosthesis connection. Two dental implants of the same type (Torque Type(®), WinSix(®), BioSAFin. S.r.l. - Ancona, Italy), with sandblasted and acid etched surfaces (Micro Rough Surface(®)), but differing from each other for the prosthesis connec...

متن کامل

Implant stability measurements using resonance frequency analysis: biological and biomechanical aspects and clinical implications.

Osseointegrated implants for prosthetic rehabilitation of the edentulous patient show high success rates if certain preconditions are fulfilled. Implant stability plays a critical role for a successful critical outcome since short implants and implants placed in soft bone are more prone to failure (13, 49). In the original protocols for implant placement, primary implant stability was ensured b...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Implant dentistry

دوره 20 1  شماره 

صفحات  -

تاریخ انتشار 2011