Validation of three deformable image registration algorithms for the thorax
نویسندگان
چکیده
Deformable image registration (DIR) has been proposed for lung ventilation calculation using 4D CT. Spatial accuracy of DIR can be evaluated using expert landmark correspondences. Additionally, image differences between the deformed and the target images give a degree of accuracy of DIR algorithms for the same image modality registration. DIR of the normal end-expiration (50%), end-inspiration (0%), midexpiration (30%), and midinspiration image (70%) phases of the 4D CT images was used to correlate the voxels between the respiratory phases. Three DIR algorithms, optical flow (OF), diffeomorphic morphons (DM), and diffeomorphic demons (DD) were validated using a 4D thorax model, consisting of a 4D CT image dataset, along with associated landmarks delineated by a radiologist. Image differences between the deformed and the target images were used to evaluate the degree of registration accuracy of the three DIR algorithms. In the validation of the DIR algorithms, the average target registration error (TRE) for normal end-expiration-to-end-inspiration registration with one standard deviation (SD) for the DIR algorithms was 1.6 ± 0.9 mm (maximum 3.1 mm) for OF, 1.4 ± 0.6 mm (maximum 3.3 mm) for DM, and 1.4 ± 0.7 mm (maximum 3.3 mm) for DD, indicating registration errors were within two voxels. As a reference, the median value of TRE between 0 and 50% phases with rigid registration only was 5.0 mm with one SD of 2.5 mm and the maximum value of 12.0 mm. For the OF algorithm, 81% of voxels were within a difference of 50 HU, and 93% of the voxels were within 100 HU. For the DM algorithm, 69% of voxels were within 50 HU, and 87% within 100 HU. For the DD algorithm, 71% of the voxels were within 50 HU, and 87% within a difference of 100 HU. These data suggest that the three DIR methods perform accurate registrations in the thorax region. The mean TRE for all three DIR methods was less than two voxels suggesting that the registration performed by all methods are equally accurate in the thorax.
منابع مشابه
A Study on Robustness of Various Deformable Image Registration Algorithms on Image Reconstruction Using 4DCT Thoracic Images
Background: Medical image interpolation is recently introduced as a helpful tool to obtain further information via initial available images taken by tomography systems. To do this, deformable image registration algorithms are mainly utilized to perform image interpolation using tomography images.Materials and Methods: In this work, 4DCT thoracic images of five real patients provided by DI...
متن کاملEvaluation of deformable image registration in HDR gynecological brachytherapy
Introduction: In brachytherapy, as in external radiotherapy, image-guidance plays an important role. For GYN treatments it is standard to acquire at least CT images and preferably MR images prior to each treatment and to calculate the dose of the day on each set of images. Then, the dose to the target and to the organs at risk (OAR) is calculated with worst case scenario from I...
متن کاملروشی جدید برای تطبیق تصاویر پزشکی همنوع برپایه مدلهای دگردیسپذیر و کاربرد آن برای تصاویر CT قفسه سینه
In 4D CT images of the thorax, deformation is caused by both the tissue movement and breathing. Tissue movement can be estimated at various time intervals by image registrstion. In this paper, a new deformable model is proposedfor non-regid medical image resgistration. The energy funational of the suggested algorithm consists of two internal (regulator) and external terms. By minimization of th...
متن کاملDeformable registration for image-guided radiation therapy.
Ths paper examines several applications of deformable registration algorithms in the field of image-guided radiotherapy. The first part focuses on the description of input and output of deformable registration algorithms, with a brief review of conventional and most current methods. The typical applications of deformable registration are then reviewed on the basis of four practical examples. Th...
متن کاملA Voxel-by-Voxel Comparison of Deformable Vector Fields Obtained by Three Deformable Image Registration Algorithms Applied to 4DCT Lung Studies
BACKGROUND Commonly used methods of assessing the accuracy of deformable image registration (DIR) rely on image segmentation or landmark selection. These methods are very labor intensive and thus limited to relatively small number of image pairs. The direct voxel-by-voxel comparison can be automated to examine fluctuations in DIR quality on a long series of image pairs. METHODS A voxel-by-vox...
متن کامل