Controlling acute inflammation with fast releasing dexamethasone-PLGA microsphere/pva hydrogel composites for implantable devices.
نویسندگان
چکیده
BACKGROUND Continuous release of dexamethasone from PLGA microsphere/PVA hydrogel composites has been shown to suppress the inflammatory tissue reaction in response to subcutaneously implanted foreign material for a period of one month. The scope of the present work is to investigate whether suppressing the initial acute inflammatory phase with fast releasing dexamethasone-PLGA microsphere/PVA composites (that release the drug over a period of one week) would prevent the development of a foreign body reaction in response to implantation in the subcutaneous tissue using a rat model. METHODS Dexamethasone loaded PLGA microspheres were prepared using the solvent evaporation method. In vitro release from microspheres was analyzed using USP apparatus 4 in phosphate buffered saline (PBS) at 37 degrees C. Composites were fabricated in 18G needles by freeze-thaw cycling the PVA/microsphere dispersion. The composites were implanted in the subcutaneous tissue of anesthetized rats. The pharmacodynamic effect was evaluated by histological examination of the tissue surrounding the composites at pre-determined time points. RESULTS In vitro release studies showed that most of the drug entrapped in the microspheres was released within one week. At days 3 and 8, these fast releasing dexamethasone containing composites suppressed the acute phase of inflammation but did not prevent the development of an inflammatory reaction after dexamethasone was completely released from the composites. By day 30, chronic inflammation and fibrosis were observed in the tissue surrounding the drug-containing composites. On days 3 and 8, the number of inflammatory cells in the vicinity of the dexamethasone containing composites was similar to that in normal tissue. However, the number of inflammatory cells was higher in drug-containing composites as compared to drug-free composites by day 30. This was due to the inflammation being in a more advanced stage in drug-free composites where a granulomatous reaction had already developed. CONCLUSION Fast release of dexamethasone from PLGA/PVA composites did not provide long-term protection against the foreign body reaction in response to implantation. It would appear that a sustained delivery of anti-inflammatory agents such as dexamethasone is necessary to suppress inflammation throughout the implant life-time.
منابع مشابه
A review of the development of a vehicle for localized and controlled drug delivery for implantable biosensors.
A major obstacle to the development of implantable biosensors is the foreign body response (FBR) that results from tissue trauma during implantation and the continuous presence of the implant in the body. The in vivo stability and functionality of biosensors are compromised by damage to sensor components and decreased analyte transport to the sensor. This paper summarizes research undertaken by...
متن کاملEffect of dexamethasone-loaded poly(lactic-co-glycolic acid) microsphere/poly(vinyl alcohol) hydrogel composite coatings on the basic characteristics of implantable glucose sensors.
BACKGROUND Hydrogels alone and in combination with microsphere drug delivery systems are being considered as biocompatible coatings for implantable glucose biosensors to prevent/minimize the foreign body response. Previously, our group has demonstrated that continuous release of dexamethasone from poly(lactic-co-glycolic acid) (PLGA) microsphere/poly(vinyl alcohol) (PVA) hydrogel composites can...
متن کاملTunable hydrogel-microsphere composites that modulate local inflammation and collagen bulking.
Injectable biomaterials alone may alter local tissue responses, including inflammatory cascades and matrix production (e.g. stimulatory dermal fillers are used as volumizing agents that induce collagen production). To expand upon the available material compositions and timing of presentation, a tunable hyaluronic acid (HA) and poly(lactide-co-glycolide) (PLGA) microsphere composite system was f...
متن کاملMicroparticles produced by the hydrogel template method for sustained drug delivery.
Polymeric microparticles have been used widely for sustained drug delivery. Current methods of microparticle production can be improved by making homogeneous particles in size and shape, increasing the drug loading, and controlling the initial burst release. In the current study, the hydrogel template method was used to produce homogeneous poly(lactide-co-glycolide) (PLGA) microparticles and to...
متن کاملPreparation of a Sustained Release Drug Delivery System for Dexamethasone by a Thermosensitive, In Situ Forming Hydrogel for Use in Differentiation of Dental Pulp
In situ forming delivery systems composed of block copolymers are attracting substantial attention due to their ease of use, biocompatibility, and biodegradability. In this study, the thermoresponsive triblock copolymer PLGA-PEG-PLGA was studied as a dexamethasone delivery system. Dexamethasone, a synthetic glucocorticoid, is used clinically to improve inflammation, pain, and the hyperemesis of...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of diabetes science and technology
دوره 1 1 شماره
صفحات -
تاریخ انتشار 2007