Review of backscatter measurement in kilovoltage radiotherapy using novel detectors and reduction from lack of underlying scattering material
نویسندگان
چکیده
Lack of underlying material can lead to dose reduction in kilovoltage radiotherapy treatments because of backscatter reduction. Conversely, the use of lead shielding can lead to large dose enhancement close to the lead interface. GAFCHROMIC film has been shown to be of use in verification of local backscatter factors compared to reference data in codes of practice, but careful handling and multiple readings are required to reduce systematic uncertainties to between 3% and 4%. Monte Carlo modeling of the specific treatment unit should be performed in cases which are found to differ from reference values before alternative values are adopted clinically, but these cases are expected to be few. GAFCHROMIC film may also be used to estimate backscatter reduction more readily than customized ionization chambers, for a range of beam qualities, applicator sizes and depth, with and without lead shielding. Differences were found between different studies, and it is not clear to what extent these are due to variation in equipment and/or technique. However, a layer of wax around lead shielding of 1 mm thickness should be sufficient to eliminate lead enhancement effects for all kilovoltage energies from 40 kV to 300 kV.
منابع مشابه
A systematic review of gold nanoparticles as novel cancer therapeutics
Objective(s):The current systematic study has reviewed the therapeutic potential of gold nanoparticles as nano radiosensitizers for cancer radiation therapy. Materials and Methods: This study was done to review nano radiosensitizers. PubMed, Ovid Medline, Science Direct, SCOPUS, ISI web of knowledge, Springer databases were searched from 2000 to September 2013 to identify appropriate studies....
متن کاملMonte Carlo Study of the Effect of Backscatter Materail Thickness on 99mTc Source Response in Single Photon Emission Computed Tomography
Introduction SPECT projections are contaminated by scatter radiation, resulting in reduced image contrast and quantitative errors. Backscatter constitutes a major part of the scatter contamination in lower energy windows. The current study is an evaluation of the effect of backscatter material on FWHM and image quality investigated by Monte Carlo simulation. Materials and Methods SIMIND program...
متن کاملThe Influence of Crystal Size and Material on Intercrystal Scattering and Parallax in PET Block Detectors: A Monte Carlo Study
Introduction: In this study, we utilized the MCNP4C Monte Carlo code to quantitatively evaluate the influence of crystal size and material on intercrystal scatter and parallax effects. Materials and Methods: For each of the 5 selected crystals (BGO, LSO, LYSO, LuAP, GSO), transport of 511 keV photons originating from a point source and incident on the central cry...
متن کاملEffects of Kilovoltage on Image Quality and Entrance Surface Dose in Lumbar Spine Digital Radiography
Introduction: Digital radiography possesses a wide dynamic range and has a major advantage in producing an acceptable image of diagnostic value even though overexposure occurs. Lumbar spine (LS) radiography is the most common examinations that gives high radiation dose to patients and accounts for the highest collective population dose of any conventional radiographic ...
متن کاملCompton scattering as a probe for materials investigation
This article investigates into the feasibility of using gamma radiation Compton backscatter spectra as a means of material characterization, with the view to developing a portable, hand held probe for investigative purposes such as searching for illicit substances hidden in wall or car door cavities.
متن کامل