Sensitive high-performance liquid chromatographic assay using 9-fluorenylmethylchloroformate for monitoring controlled-release lidocaine in plasma.
نویسندگان
چکیده
A sensitive high-performance liquid chromatographic (HPLC) assay using fluorescence detection for quantifying lidocaine levels in plasma (in the ng/ml range) was developed. This novel HPLC assay has made possible the simultaneous monitoring of lidocaine levels in coronary and peripheral plasma obtained after myocardial controlled-release matrix administration (0.92 mg/kg during 4 h) in the arrhythmic dog. The method employed extracts the drug from plasma using 1-chlorobutane and a subsequent derivatization with 9-fluorenylmethylchloroformate in acetonitrile at 110 degrees C. The derivative was chromatographed on a C18 reversed-phase column and measured with fluorescence detection (excitation 254 nm, emission 313 nm). N-Methylephedrine was found to be suitable as an internal standard, post-derivatization. The derivatization product of lidocaine was identified and characterized by mass spectral analysis. It was found to have a unique and reproducible dicarbamate structure, which was stable for at least three days at room temperature. The method was tested with human plasma as well as on dog plasma. Analytical recoveries were 88.6 +/- 3.6 and 77.4 +/- 3.0% (mean +/- S.E.), respectively, at levels ranging from 25 to 200 ng/ml. The lower detection limit was 1 ng/ml lidocaine. In conclusion, this rapid and convenient analysis was found to be suitable for the bioavailability pharmacokinetic assessment of lidocaine following low-dose regional drug administration.
منابع مشابه
Simple High-Performance Liquid Chromatographic Method for Determination of Ciprofloxacin in Human Plasma
A rapid, simple and sensitive high-performance liquid chromatography method was developed for determination of ciprofloxacin in plasma by means of ultraviolet detection. Ofloxacin was used as an internal standard and separation carried on a Novapak C18 column using a mobile phase of 0.01 M phosphate buffer (pH =2.6): methanol (82: 18 v/v). Extraction of drug was performed from plasma by liquid-...
متن کاملSimple High-Performance Liquid Chromatographic Method for Determination of Ciprofloxacin in Human Plasma
A rapid, simple and sensitive high-performance liquid chromatography method was developed for determination of ciprofloxacin in plasma by means of ultraviolet detection. Ofloxacin was used as an internal standard and separation carried on a Novapak C18 column using a mobile phase of 0.01 M phosphate buffer (pH =2.6): methanol (82: 18 v/v). Extraction of drug was performed from plasma by liquid-...
متن کاملA High-Performance Liquid Chromatographic Assay for the Determination of Losartan in Plasma
A rapid and sensitive HPLC method was developed for determination of losartan in plasma. Losartan was extracted from plasma by a two-step extraction procedure using chloroform as extracting solvent in acidic medium. HPLC analysis was performed on a cyano reversed-phase column using phosphate buffer (pH 4.3), acetonitrile (750:250, v/v) as mobile phase with a flow rate of 0.9 mL/min. Sodium dicl...
متن کاملSimple and sensitive high performance liquid chromatographic method for the simultaneous quantitation of the phenylalanine in human plasma
Phenylalanine (Phe) is the most reliable indicator for the diagnosis of phenylketonuria (PKU). The purpose of this study is to establish a reliable and quick method for the assignment of Phe in peripheral capillary blood from newborns and children by high performance liquid chromatography with ultraviolet detection (HPLC-UV). PKU is an inborn error of metabolism characterized by the inability o...
متن کاملRapid High Performance Liquid Chromatographic Method for Determination of Clarithromycin in Human Plasma Using Amperometric Detection: Application in Pharmacokinetic and Bioequivalence Studies
A rapid, sensitive and reproducible HPLC method using amperometric detector was developed and validated for the analysis of clarithromycin in human plasma. The separation was achieved on a monolithic silica column (MZ- C8 125×4.0 mm) using acetonitrile- methanol-potassium dihydrogen phosphate buffer (40:6:54,v/v), with pH of 7.5, as the mobile phase at a flow rate of 1.5 mL/min. The assay enabl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of chromatography
دوره 496 2 شماره
صفحات -
تاریخ انتشار 1989