Intracuff pressures in endotracheal and tracheostomy tubes. Related cuff physical characteristics.
نویسندگان
چکیده
This study compared intracuff pressure (ICP) during mechanical ventilation in a variety of currently used endotracheal (ET) and tracheostomy (trach) tube cuffs and related cuff physical characteristics. Tracheostomy tube physical characteristics were also measured. Variation was observed to exist between "just-seal" inspiratory and end-expiratory intracuff pressure during mechanical ventilation. Cuff diameter, thickness, compliance, geometry (shape), resting volume, and just-seal volume also varied. ICP varied with cuff diameter, thickness, compliance, geometry (shape), and trachea size, as well as tube curve and cuff position in the trachea. Thin, large-diameter, compliant cuffs generally "just seal" with relatively low ICPs. We recommend use of tracheal airways (endotracheal and tracheostomy) fitted with cuffs that seal in patients with low intracuff pressures. We also recommend nonrigid (soft) thermolabile tracheostomy tubes.
منابع مشابه
Leakage of fluid around endotracheal tube cuffs: a cadaver study
BACKGROUND The aim of the study was to evaluate the leakage of liquid past the cuffs of tracheal tubes in fresh frozen human heads. METHODS Six truncated fresh frozen heads were used and intubated with 8.0 mm endotracheal tubes. The intracuff pressures tested were 30 and 100 cmH2O. Subsequently, 20 ml of each of two oral antiseptic rinses (0.2% chlorhexidine and octenidine [octenidol®, Schülk...
متن کاملA comparison of endotracheal tube cuff pressures using estimation techniques and direct intracuff measurement.
Cuffed endotracheal tubes are one aspect of airway management designed to ensure safety, yet patients can be at risk for injury from underinflated and overinflated endotracheal cuffs. Tracheal pressures exceeding approximately 48 cm H2O impede capillary blood flow, potentially causing tracheal damage, and pressures below approximately 18 mm Hg may increase the risk of aspiration. There is no st...
متن کاملEndotracheal tube cuff pressure: need for precise measurement.
CONTEXT High compliance endotracheal tubes cuffs are used to prevent gas leak and also pulmonary aspiration in mechanically ventilated patients. However, the use of the usual cuff inflation volumes may cause tracheal damage. OBJECTIVE We tested the hypothesis that endotracheal tube cuff pressures are routinely high (above 40 cmH2O) in the Post Anesthesia Care Unit (PACU) or Intensive Care Uni...
متن کاملDirect measurement of mucosal pressures exerted by cuff and non-cuff portions of tracheal tubes with different cuff volumes and head and neck positions.
We measured directly mucosal pressures against the cuff and non-cuff portions of the tracheal tube in different head-neck positions and tested the reliability of calculated mucosal pressures, in vivo intracuff pressures and cuff volume as determinants of directly measured mucosal pressures. We studied 10 anaesthetized, paralysed adult patients. An 8.5-mm, high volume, low pressure PVC tracheal ...
متن کاملPressure on the tracheal mucosa from cuffed tubes.
During cuffed intubation, damage to the trachea is least likely when the lateral wall pressure exerted by the cuff does not exceed the mean capillary perfusion pressure of the mucosa. A study was carried out of eight different types of endotracheal tubes. At the seal point the traditional red rubber tube and the armoured latex and Softway tubes exerted pressures above the mean systemic arterial...