White , Jeffrey A . Squier , Gert Cauwenberghs and David Kleinfeld

نویسندگان

  • Jeffrey A. Squier
  • Gert Cauwenberghs
  • David Kleinfeld
  • Jonathan D. Driscoll
  • Andy Y. Shih
  • Satish Iyengar
  • Jeffrey J. Field
  • G. Allen
  • G. Allen White
چکیده

You might find this additional info useful...

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Innovative Methodology Photon counting, censor corrections, and lifetime imaging for improved detection in two-photon microscopy

Jonathan D. Driscoll, Andy Y. Shih, Satish Iyengar, Jeffrey J. Field, G. Allen White, Jeffrey A. Squier, Gert Cauwenberghs, and David Kleinfeld Department of Physics, University of California at San Diego, La Jolla, California; Department of Statistics, University of Pittsburgh, Pittsburgh, Pennsylvania; Department of Physics, Colorado School of Mines, Golden, Colorado; and Department of Bioeng...

متن کامل

Photon counting , censor corrections , and lifetime imaging for 1 improved detection in two - photon microscopy 2 3

3 Jonathan D. Driscoll, Andy Y. Shih, Satish Iyengar, Jeffrey J. Field, 4 G. Allen White, Jeffrey A. Squier, Gert Cauwenberghs and David Kleinfeld 5 6 Department of Physics, University of California at San Diego, La Jolla, CA 7 Department of Statistics, University of Pittsburgh, Pittsburgh, PA 8 Department of Physics, Colorado School of Mines, Golden, CO 9 Department of Bioengineering, Universi...

متن کامل

Photon counting, censor corrections, and lifetime imaging for improved detection in two-photon microscopy.

We present a high-speed photon counter for use with two-photon microscopy. Counting pulses of photocurrent, as opposed to analog integration, maximizes the signal-to-noise ratio so long as the uncertainty in the count does not exceed the gain-noise of the photodetector. Our system extends this improvement through an estimate of the count that corrects for the censored period after detection of ...

متن کامل

on estimating the true emission count for “ Photon counting , censor corrections , and lifetime imaging for improved detection in two - photon microscopy ”

For each experimental run, we assume that the number of photocurrent events, i.e., detected fluorescent emission events, N , is a Poisson random variable with mean α. If N = n ≥ 1, then let W1, . . . ,Wn be the times of the N emissions; we assume that each Wi is exponentially distributed and that the emission times are independent of the number of emissions. For all calculations below, our cloc...

متن کامل

Plasma-mediated ablation: an optical tool for submicrometer surgery on neuronal and vascular systems.

Plasma-mediated ablation makes use of high energy laser pulses to ionize molecules within the first few femtoseconds of the pulse. This process leads to a submicrometer-sized bubble of plasma that can ablate tissue with negligible heat transfer and collateral damage to neighboring tissue. We review the physics of plasma-mediated ablation and its use as a tool to generate targeted insults at the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011