A comparative evaluation of impact strength of conventionally heat cured and high impact heat cured polymethyl methacrylate denture base resins: an in vitro study.

نویسندگان

  • R Narendra
  • N Simhachalam Reddy
  • Sashi Deepth Reddy
  • C R Sashi Purna
  • M Chandra Shekar
  • S Balasubramanyam
چکیده

UNLABELLED The denture bases made by using polymethyl methacrylates of Acrylic resin family have excellent physical properties, simple to process and easy to reline, rebase and repair. One of the inherent disadvantages of this material is the liability to break during function. The strength assessment of acrylic resins have been made generally by transverse defection tests. AIM To evaluate the impact strength valves of certain brands of commercially available denture base resins and suggest their suitability. MATERIALS AND METHODS The denture bases we made using polymethyl methacrylates of acrylic resin family because they have excellent physical properties, simple to process and easy to reline and rebase. Six commercial brands of polymethyl meth- acrylate, namely Stellon (DPI-India), Acralyn-H (Asian Acrylate, India), Trevalon (Dentsply-England), Lucitone 199 (Dentsply/ York division), Acralyn-H (Super Unbreakable), Trevalon HI (Dentsply, Detray division, England) were tested by breaking them using Analog Pendulum (ASTM D 256). RESULTS From the entire study the maximum impact strength was reported for Acralyn-H super unbreakable (Asian Acrylates, India) 62.19 joules. CONCLUSION All the analysis led to conclusion that there is basic change in material composition within and among the different groups of denture base resins. CLINICAL IMPLICATIONS The complete dentures made using denture base resins with high impact strength valves (e.g. Acralyn-H super unbreakable) will be more durable and can be used by the patient for considerable period of time, i.e. beyond 4 to 5 years.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative Evaluation of the Flexural Strength of Heat Polymerized Acrylic Resin with the Addition of 8% and 13% Aluminum Oxide Powder: An In-vitro Study

Introduction: Acrylic resins have been used successfully as denture bases. However, acrylic resin denture base materials are brittle and have poor strength and thermal conductivity. Therefore, it is essential to improve the flexural strength of heat polymerized acrylic resin. The present study aimed to evaluate and compare the flexural strength of heated polymerized acrylic res...

متن کامل

The effect of fiber reinforcement on the dimensional changes of poly methyl methacrylate resin after processing and after immersion in water: an in vitro study.

AIMS AND OBJECTIVES To evaluate and compare the effect of fiber reinforcement on the dimensional changes of heat-cured poly (methyl methacrylate) resin after processing and immersion in water. MATERIALS AND METHODS Three different heat-cure resins were selected for the present study: (1) Nonreinforced heat-cure methyl methacrylate resin, (2) High Impact heat-cured methyl methacrylate resin an...

متن کامل

Impact of Packing and Processing Technique on Mechanical Properties of Acrylic Denture Base Materials

The fracture resistance of polymethylmethacrylate (PMMA) as the most popular denture base material is not satisfactory. Different factors can be involved in denture fracture. Among them, flexural fatigue and impact are the most common failure mechanisms of an acrylic denture base. It has been shown that there is a correlation between the static strength and fatigue life of composite resins. The...

متن کامل

Effect of Thermocycling and Polyethylene Fibre Addition on Impact and Transversal Strength of Heat Cured Acrylic Resin Denture Base Material

Background: Heat cured acrylic resin is the most widely used material in the manufacture ofdenture base, but has mechanical properties weakness (transversal strength and impact strength). Alternative to increase the mechanical properties of acrylic resin is the utilization of reinforcing fibre that is polyethylene fibre that has advantage such as good aesthetic, easy to manipulate and increase ...

متن کامل

Erratum - Influence of various metal oxides on mechanical and physical properties of heat-cured polymethyl methacrylate denture base resins

PURPOSE To evaluate the effect of various metal oxides on impact strength (IS), fracture toughness (FT), water sorption (WSP) and solubility (WSL) of heat-cured acrylic resin. MATERIALS AND METHODS Fifty acrylic resin specimens were fabricated for each test and divided into five groups. Group 1 was the control group and Group 2, 3, 4 and 5 (test groups) included a mixture of 1% TiO2 and 1% Zr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The journal of contemporary dental practice

دوره 14 6  شماره 

صفحات  -

تاریخ انتشار 2013