Optimal digital filtering requires a different cut-off frequency strategy for the determination of the higher derivatives.

نویسندگان

  • G Giakas
  • V Baltzopoulos
چکیده

The present study investigated four different filtering and differentiation sequences for the calculation of the higher derivatives from noisy displacement data when using a second-order Butterworth filter and first-order finite differences. These were: (1) the conventional sequence (i.e. filtering the displacement data and then differentiating); (2) filtering the displacement with a different cut-off frequency depending upon optimal 0th, 1st and 2nd derivatives; (3) double filtering and differentiation (only for acceleration); and (4) differentiation and then filtering separately in each derivative domain, i.e. treating the noisy higher derivatives as individual signals. Thirty levels of time domain and 30 levels of frequency domain computer-generated pure noise signals, were superimposed on 24 reference signals which simulated the medial-lateral, anterior-posterior and vertical displacement patterns of eight markers attached to the lower extremity segments during walking. The optimum cut-off frequency for the displacement velocity and acceleration data was calculated as the one that produced the minimum root mean square error between the reference and noisy data in each derivative domain. The results indicated that the conventional strategy has to be reconsidered and modified, as the best results were obtained by the second strategy. The optimum cut-off frequency for acceleration was lower than that required for the velocity which in turn was lower than the optimum cut-off frequency for displacement. The findings of the present study will contribute to the development of existing and future automatic filtering techniques based on digital filtering.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Relationship between the optimum cut off frequency for Butterworth filter and lung-heart ratio in 99mTc myocardial SPECT

Background: We investigated whether the lungheart ratio parameter (LHR) can be used to identify the optimum cut off frequency for Butterworth filter in 99mTc myocardial SPECT imaging. Materials and Methods: This study involved a cardiac phantom system consisting of cardiac insert in which 1.10 cm cold defect was inserted into its myocardium wall and filled with 4.0 μCi/ml (0.148 MBq/ml...

متن کامل

Optimal High Frequency Cut-off in SWAN Wave Model

This study investigates the importance of selecting an appropriate cut-off frequency in the SWAN model when it is applied to areas with limited fetches. In SWAN, the cut-off frequency is a constant value set by user in the model, and its appropriate selection plays an important role in the accuracy and optimization of the wave model; very high value increases the computational cost and might le...

متن کامل

Digital Filtering of Three-Dimensional Lower Extremity Kinematics: an Assessment

Errors in kinematic data are referred to as noise and are an undesirable portion of any waveform. Noise is typically removed using a low-pass filter which removes the high frequency components of the signal. The selection of an optimal frequency cut-off is very important when processing kinematic information and a number of techniques exists for the determination of an optimal frequency cut-off...

متن کامل

محاسبه Cut-off point مناسب برای آزمون ELISA جهت تشخیص بروسلوز انسانی در ایران

Background: Finding a reliable diagnostic method for brucellosis is the most challengeable problem. In this study we determined the optimal diagnostic cut-off point for ELISA test.Methods: We gathered 56 confirmed cases of brucellosis. Furthermore blood samples from 126 controls including 73 healthy controls and 53 without brucellosis febrile patients were collected. In all of the cases and con...

متن کامل

Determination of optimum filter in myocardial SPECT: A phantom study

Background: In myocardial perfusion SPECT imaging, images are degraded by photon attenuation, the distance-dependent collimator, detector response and photons scatter. Filters greatly affect quality of nuclear medicine images Materials and Methods: A phantom simulating heart left ventricle was built. About 1mCi of 99mTc was injected into the phantom. Images were taken from this phantom. Some fi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomechanics

دوره 30 8  شماره 

صفحات  -

تاریخ انتشار 1997