Is a hollow centralizer necessary when using a polished, tapered, cemented femoral stem?
نویسندگان
چکیده
Background and purpose - A tapered, polished and collarless stem is normally equipped with a hollow centralizer to prevent the stem from becoming end-bearing in the cement as the stem subsides. In a randomized clinical trial, we evaluated such a stem (MS-30), which was initially introduced with a solid centralizer but was later recommended to be fitted with a hollow centralizer. We hypothesized that while the stem would sink more, it would become rotationally stable and have less retroversion with a hollow centralizer than with a solid centralizer. Patients and methods - We randomized 60 patients with primary hip arthritis to receive either a hollow centralizer or a solid centralizer with the stem. The effect was evaluated over a 10-year follow-up period with repeated RSA examinations, conventional radiographs, and clinical follow-ups using the WOMAC and SF-12 questionnaires. Results - At 10-year follow-up, the group with hollow centralizers had subsided more than the group with solid centralizers (1.99 mm (hollow) as opposed to 0.57 mm (solid); p < 0.001). However, rotation was similar at 10-year follow-up (mean retroversion 1.34° (hollow) and 1.30° (solid)). Both groups showed excellent 10-year results, with similar clinical outcome, and none of the stems were radiographically loose or had been revised. Interpretation - As expected, there was more subsidence in the group with hollow centralizers, and with similar magnitude to that reported in earlier RSA studies on conceptually similar prostheses. Interestingly, there was no difference in the rotational behavior of the prostheses. This stem type appears to have a design that, regardless of the type of centralizer and the possibility of subsidence, withstands the rotational forces it is subjected to very well. This study does not support the need for a hollow centralizer for these types of stems.
منابع مشابه
Total Hip Arthroplasty Using a Polished Tapered Cemented Stem in Hereditary Multiple Exostosis
A 61-year-old Japanese man underwent right total hip arthroplasty for hereditary multiple exostosis. At first presentation, he had suffered from coxalgia for a long time. On radiographic images, there was a gigantic femoral head, increased shaft angle, and large diameter of the femoral neck. He had also developed coxarthrosis and severe pain of the hip joint. The transformation of the proximal ...
متن کاملSubstantially higher prevalence of postoperative periprosthetic fractures in octogenarians with hip fractures operated with a cemented, polished tapered stem rather than an anatomic stem
Background and purpose - Recent studies have demonstrated a high incidence of postoperative periprosthetic femoral fracture (PPF) in elderly patients treated with 2 commonly used cemented, polished tapered stems. We compared the prevalence and incidence rate of PPF in a consecutive cohort of octagenerians with femoral neck fractures (FNFs) treated with either a collarless, polished tapered (CPT...
متن کاملFive-year prospective clinical and radiological results of a new cannulated cemented polished Tri-Taper femoral stem.
We describe the results at five years of a prospective study of a new tri-tapered polished, cannulated, cemented femoral stem implanted in 51 patients (54 hips) with osteoarthritis. The mean age and body mass index of the patients was 74 years and 27.9, respectively. Using the anterolateral approach, half of the stems were implanted by a consultant orthopaedic surgeon and half by six different ...
متن کاملRadiographic evaluation of cementation technique using polished, conical, triple-tapered femoral stem in hip arthroplasty☆
OBJECTIVE To radiographically evaluate the quality of cementation and implantation technique using a polished, triple-tapered femoral stem in total hip arthroplasty (THA). METHOD Retrospective study with radiographic evaluation of 86 hips in 83 patients who underwent to primary THA with the triple-tapered cemented femoral stem C-Stem (DePuy Orthopedics, Warsaw, Indiana). Cases with at least o...
متن کاملHigh risk of early periprosthetic fractures after primary hip arthroplasty in elderly patients using a cemented, tapered, polished stem
BACKGROUND AND PURPOSE Postoperative periprosthetic femoral fracture (PPF) after hip arthroplasty is associated with considerable morbidity and mortality. We assessed the incidence and characteristics of periprosthetic fractures in a consecutive cohort of elderly patients treated with a cemented, collarless, polished and tapered femoral stem (CPT). PATIENTS AND METHODS In this single-center p...